SAMES KREMLIN AIRMIX 20C50 GT Documentation page 13

Table of Contents

Advertisement

REVERSING BLOCK (REFER TO DOC. 573.087.040)
Guards (air motor cover, coupling shields, housings ...) have been designed for
The manufacturer will not be held responsible for bodily injury or failure and / or
damage to property due to removal or partial removal of the guards
Disassemble cover (32) by removing screws CHc (33).
Dissociate female yoke (12) from reversing block lever (9).
Dismount reversing block by removing screws (10 and 8).
Reinstall the new reversing block in the reverse order of the
disassembly sequence.
 CAUTION : The number of spirals must equally be
distributed on each fastening parts in order to get the
above dimension.
Before reassembling the different components :
-
Clean the parts with the appropriate cleaning solvent.
-
Install new seals if it is necessary after having lubricated them with PTFE grease.
-
Install new parts if it is necessary.
SAMES KREMLIN
safe use of the equipment.
- 2 -
31.85 mm ±0.5
N° : 578.163.110-UK-1903