Zephyr
WARRANTY SERVICE: Please read warranty information first
If after reviewing the troubleshooting tips the unit will still not work, you should return it to the
Dealer where you purchased it. They may be able to further evaluate the unit and test its various
components and quite possibly will be able to identify and/or fix any problems. If the Dealer is
The Zephyr™ 3 is used to maintain the temperature level in your growing environment.
unable to fix the unit, they will return it to us for factory repair.
The temperature can be adjusted by setting the dial on the front of the controller to your
If there are no Dealers in your area, you may contact us directly for technical support. If we
preferred setting. When the Zephyr™ 3 is in the COOLING MODE and the temperature
cannot help you resolve the problem over the phone, we will issue you a Return Merchandise
exceeds the predetermined setting, the piggyback cord set is activated and will operate the
Authorization (RMA) number authorizing you to return the unit to us for factory reconditioning
exhaust fan until the temperature is lower than the preferred set point. When the Zephyr™
(if the controller is currently under warranty). Contact the number below for a RMA number and
3 is in the HEATING MODE and the temperature is below the predetermined setting, then
shipping address. Please complete the form below and include it with your unit, and write the
the piggyback cord set is activated and will operate the heater (1500 Watts or less) until the
RMA number clearly on the outside of the box.
temperature is higher than the preferred set point. The Zephyr™ 3 operates up to 15 amps
Please package the unit in its original packaging. If it is damaged in shipment we cannot be held
maximum capacity on a standard 120 Volt circuit. Built with the highest quality components,
responsible. Insuring the parcel is recommended.
the Zephyr™ 3 will provide the user with years of trouble free service. Controllers created for
Once we receive the unit back, we will repair it within 48 hours (business) and return it to you
our industry, by our industry!
freight prepaid via UPS ground shipment.
Include the following if returning directly to Titan Controls
Proof of purchase
Return Merchandise Authorization Number (Required)_____________________________________________
• Securely mount your Zephyr™ 3 in your grow area and away from any moisture, spray,
pesticides, etc. using the hardware provided.
Company Name: ____________________________________________________________________________________
• Set green rocker switch in either COOLING or HEATING mode.
Contact Name: _____________________________________________________________________________________
• Plug the exhaust fan or heater into the piggyback cord set.
Address: __________________________________________________________________________________________
• Turn the fan 'ON' to the fastest setting possible, if adjustable.
____________________________________________________________________________________________________
• OR set the heater at the highest setting possible, if adjustable.
• Set the 'Temperature' dial at the preferred temperature level for your garden.
Phone #: ___________________________________________________________________________________________
• Finally, plug the Zephyr™ 3 into a dedicated 120 Volt – 15 Amp power source.
Email address: _______________________________________________________________________________
• Use of a surge protection device is recommended to protect your Zephyr™ 3 from
potential power damage in areas where this may be an issue.
What is the nature of the problem? ____________________________________________________________
• Your Zephyr™ 3 will now control your equipment at the desired setting.
_____________________________________________________________________________________________
_____________________________________________________________________________________________
_____________________________________________________________________________________________
_____________________________________________________________________________________________
_____________________________________________________________________________________________
If the Zephyr™ 3 is not performing as expected, try the following:
_____________________________________________________________________________________________
a. Confirm that your power input source is active by using a voltage test meter, and verify
that the power input source is providing 120 Volts of power to the Zephyr™ 3.
Send to your nearest location – shipping address will be given when the RMA # is issued:
b. Validate that the power outlet of the Zephyr™ 3 is active by setting the switch in the
www.titancontrols.net
COOL mode and put the temperature dial at the lowest setting. Then use a voltage test
meter to verify power is flowing through the controller to the power outlet.
For technical assistance call us at 1-888-80-Titan or 1-888-808-4826.
3 – Heating/Cooling
Controller Overview
Instructions for Operation
This completed form
Troubleshooting Tips
®
RMA # on the outside of the box
7
3