AES/EBU In to CobraNet:
channels.
CobraNet to AES/EBU Out:
outputs.
Store/Recall:
AES/EBU input and output to CobraNet channel assignments. There are 100 patch mem-
ories. Patch #0 is a read-only memory containing initial assignments, with each AES/EBU
input and output assigned to the correspondingly numbered CobraNet input and output.
For example, AES/EBU input #1 is assigned to CobraNet output #1, AES/EBU input #2 is
assigned to CobraNet output #2, and so on. Up to 99 patches can be stored in patch mem-
ories 1 through 99.
To store a patch, use the Up and Down arrow buttons to select a patch memory from 1 to
99, enter a title, and then click the Store button. The patch is immediately transferred to,
and stored in the NHB32-C, where it is can be recalled directly from the front panel.
To recall a patch, use the Up and Down arrow buttons to select a patch memory from 0 to
99, and then click the Recall button.
When a patch is edited, the "EDIT" indicator appears next to the patch number. It disap-
pears when the patch is stored or another patch is recalled.

Word Clock Page

This page is used to select the NHB32-C's wordclock source.
Master clock:
UNLOCK. It works in unison with the LOCK indicator on the NHB32-C's front panel.
Word clock source select:
source, which can be a pair of AES/EBU inputs, the CobraNet network, or the NHB32-C's
BNC WORD CLOCK IN connector. A confirmation message appears when you change the
wordclock source. The wordclock source can also be selected on the NHB32-C's front panel.
Note: When you change the wordclock settings of your system, some devices may output noise,
so turn down your power amps beforehand, otherwise you may damage your speakers.
This tab is used to assign AES/EBU inputs to CobraNet
This tab is used to assign CobraNet channels to AES/EBU
These buttons are used to store and recall patches. A patch consists of all
This indicator shows the wordclock lock status of the NHB32-C: LOCK or
These options are used to select the NHB32-C's wordclock