ACU Pages

Amp Pages

The Amp pages are used to control and monitor power
amplifiers. There are four Amp pages: Amp 00–07, Amp
08–15, Amp 16–23, and Amp 24–31. Each page can display
the channels of up to eight power amplifiers. Power amplifi-
ers can have 2, 4, 6, or 8 channels. The screen shot shown here
features two channels of a PC9500N power amplifier.
Amp name:
Only the first 21 letters of the name are displayed. To display
the name in full, place the mouse pointer over the name.
POWER button:
amplifier to On or Standby.
Mode indicator:
for each pair of channels: STEREO, PARALLEL, or BRIDGE.
Channel name:
play the name in full, place the mouse pointer over the name.
To name a channel, right-click its icon in the network tree
and choose Rename from the pop-up menu.
PROTECT indicator:
protection system is displayed here. Normally there's no indi-
cation. If the amplifier's protection system is activated, for
example, the power supply to the power amplifier's driver
section fails because of overheating, "PROTECT" is dis-
played. It's also displayed if the power amplifier is set to
Standby by clicking the POWER button in NetworkAmp
Manager.
Output CLIP indicator:
when the channel is clipping.
Output meter:
nel's output level in either watts or volts (see preference on
page
Impedance indicator:
impedance.
Temp meter:
nel's temperature in either centigrade or Fahrenheit (see
preference on
the temp peak hold value. The numerical value below the
meter is the current temperature. To reset peak temp hold,
right-click the meter and choose "Reset temp hold on this
channel" or "Reset temp hold on all channels" from the
pop-up menu.
Input meter:
ATT fader:
the fader is the current attenuation setting in dB. Attenuation can also be set by clicking the
Up and Down arrow buttons, or by entering a value from the keyboard.
Phase button:
Reversed.
Mute button:
NetworkAmp Manager—Owner's Manual
This displays the power amplifier's name.
This button is used to set the power
This displays the power amplifier mode
Channel names are displayed here. To dis-
The status of the power amplifier's
This indicator lights up red
This 12-segment meter displays the chan-
8).
This displays the channel's load
This 12-segment meter displays the chan-
page
8). The value on the right of the meter is
This 12-segment meter displays the channel's input level in dB.
This fader attenuates the channel's input signal. The numerical value below
This button is used to set the channel's input signal phase: Normal or
This button is used to mute the channel.
PROTECT indicator

Advertisement

Table of Contents