Toyotomi TRN-828ZR User Manual page 39

Wall mounted air conditioner inverter type
Hide thumbs Also See for TRN-828ZR:
Table of Contents

Advertisement

Available languages

Available languages

Installation of indoor unit
Step 8: bind up pipe
1. Bind up the connection pipe, power
cord and drain hose with the band.
indoor
unit
2. Reserve a certain length of drain
hose and power cord for installation
when binding them. When binding to
a certain degree, separate the indoor
power and then separate the drain
hose.
Step 9: hang the indoor unit
1.
Put the bound pipes in the wall pipe and then make them pass through the wall hole.
2.
Hang the indoor unit on the wall-mounting frame.
3.
Stuff the gap between pipes and wall hole with sealing gum.
4.
Fix the wall pipe.
5.
Check if the indoor unit is installed firmly and closed to the wall.
indoor
wall pipe
NOTE:
Do not bend the drain hose too excessively in order to prevent blocking.
indoor and outdoor
power cord
gas
pipe
liquid
pipe
band
drain hose
outdoor
sealing gum
connection pipe
indoor power cord
3. Bind them evenly.
4. The liquid pipe and gas pipe should
be bound separately at the end.
NOTE:
The power cord and control wire can't
be crossed or winding.
The drain hose should be bound at the
bottom.
lower hook of
wall-mounting frame
39
drain hose
band
upper hook
GB