MAINTENANCE
PREVENTATIVE
MAINTENANCE
i
!
CAUTION
CAUTION! Do NOT beat
strainers to remove
soil and debris!

PREVENTATIVE MAINTENANCE

The manufacturer highly recommends that any maintenance and repairs not specifically
discussed in this manual only be performed by qualified service personnel.
Performing maintenance on the machine may void a warranty.
By following the operating and cleaning instructions in this manual, users should get
the most efficient results from the machine. As a reminder, here are some steps to
ensure that the machine is used properly:
Ensure water temperatures match those listed on the machine data plate
(behind the door).
Remove as much soil as possible from ware before loading into racks.
Ensure all strainers are in place and free of soil and debris before operating the
machine. To clean strainers, wipe them out with a rag and rinse under a faucet.
A toothpick can be used to dislodge any stubborn debris. Do not beat strainers
on waste cans; once bent they will not work properly.
If hard water is present, install a water softener or SPS into the water line
connecting to the machine (see Plumbing section).
Ensure wash/rinse arm is secure in the machine before operating.
Ensure the drain stopper is in place before operating.
Do not overfill racks.
Ensure glasses are placed upside-down in the rack.
Ensure all chemicals being injected into the machine have been verified at the
correct concentrations.
Clean out the machine at the end of every workday per the Shutdown and
Cleaning section.
Follow all safety procedures, whether listed in this manual or put forth by local,
state, or national codes/regulations.
15