Preventative Maintenance - Jackson DISHSTAR HT-E Installation, Operation And Service Manual

Hide thumbs Also See for DISHSTAR HT-E:
Table of Contents

Advertisement

MAINTENANCE
PREVENTATIVE
MAINTENANCE
i
!
CAUTION
CAUTION! Do NOT beat
strainers to remove
soil and debris!
07610-004-43-79-Q

PREVENTATIVE MAINTENANCE

The manufacturer highly recommends that any maintenance and repairs not specifically
discussed in this manual only be performed by qualified service personnel. Performing
maintenance on the machine may void a warranty.
By following operating and cleaning instructions in this manual, users should get
the most efficient results from the machine. As a reminder, here are some steps to
ensure the machine is used properly:
1. Ensure water temperatures match those listed on machine data plate (on front-
left of machine).
SERIAL NO.:
XXXXXXXXX
60Hz
1 PH
2 WIRE
MODEL: DISHSTAR HT-E
208 VOLT
230 VOLT
WASH MOTOR
1 HP
5.0 A
1 HP
5.0 A
WASH HEATER
3.3 KW
15.9 A
4 KW
17.4 A
RINSE HEATER
4.1 KW
19.7 A
24.7 A
5 KW
21.7 A
26.7 A
TOTAL LOAD
NOTE: WASH AND RINSE HEATER DO NOT OPERATE
Conforms to NSF Std 3
4000897
AT THE SAME TIME. ELECTRICAL LOADS BASED ON WASH
MOTOR AND RINSE HEATER (HIGHEST AMP DRAW)
OPERATING PARAMETERS
MINIMUM WASH TEMP
155°F
MINIMUM RINSE TEMP
180°F
Intertek
MIN. INCOMING WATER TEMP
110°F
4000897
WASH CYCLE TIME
80 SEC
Conforms to UL Std 921
Conforms to CSA
RINSE CYCLE TIME
9 SEC
Std C22.2 No.168
WATER FLOW PRESSURE
10 PSI
CAUTION: IF THIS MACHINE IS CONNECTED TO A CIRCUIT PROTECTED BY FUSES,
U S E
O N L Y
3 0 A
N O N - T I M E
D E L A Y
F U S E
O R
O V E R C U R R E N T
PROTECTION.
ATTENSION: SE CONNECTER A UN MINIMUM D'ALIMENTATION 30 AMPERES
DELAI FUSIBLE DE TYPE NON-TEMPS OU LA PROTECTION CONTRE LES SURINTENSITES.
MINIMUM CIRCUIT AMPACITY
@208 VOLTS: 26.0 AMPS
Made in the USA
@230 VOLTS: 28.0 AMPS
Jackson WWS , Inc
6209 N US HWY 25E
MAXIMUM OVERCURRENT PROTECTION
Gray, KY 40734
@208 VOLTS: 30 AMPS
@230 VOLTS: 30 AMPS
(606) 523-9795
09905-004-42-87D
2. Remove as much soil as possible from ware before loading into racks.
3. Ensure strainers are in place, laying flat in tub, and free of soil and debris before
operating machine. To clean strainers, wipe out with a rag and rinse under a
faucet. For stubborn debris, a toothpick can be used. Do not beat strainers on
waste cans; once bent, they will not work properly.
4. Ensure all wash and rinse arms are secure in machine before operating.