Geyser ALLEGRO Manual page 14

Water purification system on the basis of the reverse osmosis 8l, 12l, 16l
Table of Contents

Advertisement

Water leak
Fittings are not tightened
The system has just started to
operate
There is too little
water outflowing
from the storage
tank
The excessive pressure is low
in the storage tank
The pressure in the supply
main is reduced, and, as a
The storage tank
consequence, the automatic
is full, but the
switch does not operate
water flows to
the drainage
The automatic switch is
malfunctioning
Water stagnation in the filter or
the storage tank for a long time
Water has a taste
The carbon post-filter has
or foul smell
exhausted its resource
Remainder of a preservative
agent in the storage tank
The pressure in the supply
main is reduced, and, as a
The drain flux
consequence, the automatic
is not shut after
switch does not operate
filling of the
storage tank
The automatic switch is
malfunctioning
The automatic switch shuts the source water supply to the osmosis at the maximum
filling of the storage tank that prevents water permanent drain to the drainage.
The low pressure controller is used for disconnecting the reverse osmosis system at a
drop in pressure in the water conduit.
The high pressure controller is used for disconnecting the reverse osmosis system at the
storage tank filling with the purified water.
The drain flux limiter maintains the required pressure on the reverse-osmosis membrane
by limiting the wasted water outflow to the drainage.
14
Tighten connections
Increase the
pressure
Install the facility
increasing a
pressure
Replace
Wash the system
with water and refill
the tank
Replace
Drain water from the
tank and refill it
Install the pressure
increase unit
Replace
ADDITIONS
The tank filling can
be from 4 hours to 6
hours depending on
the water temperature
and the pressure in
the main
The normal pressure
in the empty tank
should be 0.4-0.5
atm.
The automatic switch
steadily operates at
the pressure of more
than 2.5 atm.
The automatic switch
cannot operate due to
a production defect
The automatic switch
steadily operates at
the pressure of more
than 2.5 atm.
The automatic switch
cannot operate due to
a production defect