Servicing the Planetary Oil

Oil Specifications
Oil type: SAE 80W-90, API service GL-5
Capacity: 0.70 L (24 fl oz)
Checking the Planetary Oil Level
Service Interval: Before each use or daily
1.
Park the machine on a level surface, disengage
the auxiliary hydraulics, engage the parking
brake, and lower the loader arms.
2.
Shut off the engine and remove the key.
3.
Remove the upper drain plug, at the 3 o'clock
position on the planetary, near the quick-attach
plate
(Figure
10).
4.
If oil comes out of the hole, the oil level is
correct. If no oil comes out, add oil until it comes
out of the hole.
Important:
Do not overfill.
5.
Install the plug.
Figure 10
1. Lower drain plug
g272152
2. Upper drain plug
Replacing the Planetary Oil
Service Interval: Every 50 hours
1.
Park the machine on a level surface, disengage
the auxiliary hydraulics, engage the parking
brake, and lower the loader arms.
2.
Shut off the engine and remove the key.
3.
Remove the lower drain plug, at the 6 o'clock
position on the planetary, and drain the oil
(Figure
10).
4.
Install the drain plug.
5.
Remove the upper drain plug and add oil until it
comes out of the hole.
6.
Install the drain plug.
7.
Dispose of the used oil at a recycling center.