Siemens SIMATIC S5 1P 243 Equipment Manual page 50

Analog module with fb 160, fb 161
Hide thumbs Also See for SIMATIC S5 1P 243:
Table of Contents

Advertisement

Interrupt Processing
Binary signal/interrupt jumpering:
Pin Signal
No.
1 +24V
2 +24V
m
Binary input O
Binary input 1
12 Bll
Binary input 2
13 B12
14 B13
Binary input 3
15 B14
Binary input 4
Binary input 5
16 B15
m
Binary input 6
17 B16
18 B17
Binary input 7 ,
Comparator 1
Comparator 2
Binary output O
3 BOO
4 BO1
Binary output 1
Binary output 2
5 B02
Binary output 3
- 6 B03
Binary output 4
7 B04
Binary output 5
8 B05
Binary output 6
9 B06
10 B07 4
42 M
43 M ~;
F+
10
11
12
4 – 18
I
2
5
6
12 SIMATIC S5
15
19
1
2
3
4
5
1
6
7
4
8
9
5
6
7
Buffer
interrupt processing
Interrupt Module
6ES5432–4UA1 1