Belden grass valley MV-800 Series User Manual
Belden grass valley MV-800 Series User Manual

Belden grass valley MV-800 Series User Manual

Integrated multiviewer for sirius 800 routers
Table of Contents

Advertisement

Quick Links

MV-800
INTEGRATED MULTIVIEWER FOR SIRIUS 800 ROUTERS
User Manual
RMY3 MV-800-UM Issue 2 Revision 1
2019 March 14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the grass valley MV-800 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Belden grass valley MV-800 Series

  • Page 1 MV-800 INTEGRATED MULTIVIEWER FOR SIRIUS 800 ROUTERS User Manual RMY3 MV-800-UM Issue 2 Revision 1 2019 March 14...
  • Page 2: Patent Information

    Copyright and Trademark Notice Copyright © 2019, Grass Valley Canada. All rights reserved. Belden, Belden Sending All The Right Signals, and the Belden logo are trademarks or registered trademarks of Belden Inc. or its affiliated companies in the United States and other jurisdictions.
  • Page 3: About This Manual

    MV-800 User Manual About this Manual Thank you for purchasing your new MV-800 Integrated Multiviewer. This MV-800 user manual describes how to install, configure and operate the MV-800 multiviewer in the Sirius 830, 840 and 850 routers. Refer to the appropriate Sirius 800 Router Installation Manuals for details on how to unpack, install and test a Sirius 800 router.
  • Page 4: Important Safety Information

    Notices Important Safety Information This section provides important safety guidelines for operators and service personnel. Specific warnings and cautions appear throughout the manual where they apply. Please read and follow this important information, especially those instructions related to the risk of electric shock or injury to persons.
  • Page 5 MV-800 User Manual The presence of this symbol in or on Grass Valley product means that it complies with all applicable European Union (CE) directives. The presence of this symbol in or on Grass Valley product means that it complies with safety of laser product applicable standards.
  • Page 6: Electrostatic Discharge (Esd) Protection

    Notices • Do not operate with suspected equipment failure. If you suspect product damage or equipment failure, have the equipment inspected by qualified service personnel. • To reduce the risk of electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
  • Page 7 MV-800 User Manual Mesures de sécurité et avis importants La présente section fournit des consignes de sécurité importantes pour les opérateurs et le personnel de service. Des avertissements ou mises en garde spécifiques figurent dans le manuel, dans les sections où ils s’appliquent. Prenez le temps de bien lire les consignes et assurez-vous de les respecter, en particulier celles qui sont destinées à...
  • Page 8 Notices Le marquage CE indique que l’appareil visé est conforme aux exigences essentielles des directives applicables de l’Union européenne en matière de sécurité électrique, de compatibilité électromagnétique et de conformité environnementale. Le symbole ci-contre sur un appareil Grass Valley ou à l’intérieur de l’appareil indique qu’il est conforme aux normes applicables en matière de sécurité...
  • Page 9 MV-800 User Manual • Les produits qui n'ont pas d’interrupteur marche-arrêt et qui disposent d’une source d’alimentation externe doivent être installés à proximité d'une prise de courant facile d’accès. • Si l’équipement n’est pas pourvu d’un modules d’alimentation auto-adaptables, vérifiez la configuration de chacun des modules d'alimentation avant de les mettre sous tension.
  • Page 10: Environmental Information

    Notices Précautions pour les écrans LCD et TFT Regarder l’écran pendant une trop longue période de temps peut nuire à votre vision. Prenez une pause de 10 minutes, après 30 minutes d’utilisation. Si l'écran LCD ou TFT est brisé, manipulez les fragments de verre avec précaution au moment de vous en débarrasser.
  • Page 11: Warnings And Precautions

    MV-800 User Manual Warnings and Precautions The hardware modules covered by this user manual are not mains powered. The hardware modules must be fitted into a mains powered frame, host equipment, for operation. Safety Warnings CAUTION RISK OF ELECTRIC SHOCK DO NOT REMOVE COVERS NO USER SERVICABLE PARTS REFER SERVICING TO QUALIFIED...
  • Page 12 Notices 3 Gently remove the battery from its holder using a blunt instrument for leverage such as a screwdriver if necessary. In some cases the battery will need to be desoldered from the PCB. 4 Dispose of the battery and equipment according to your local environmental laws and guidelines.
  • Page 13: Cable Management

    MV-800 User Manual Cable Management It is important that the cabling to and from the multiviewer is correctly labeled and routed. This will simplify the work required if the installation needs to be changed or added to at a future date.
  • Page 14: Safety And Emc Standards

    Notices Safety and EMC Standards This equipment complies with the following standards: Safety Information Technology Equipment - Safety Part 1 EN60950-1: 2006 Safety of Information Technology Equipment Including Electrical Business Equipment. UL1419 (4 Edition) Standard for Safety – Professional Video and Audio equipment (UL file number E193966) EMC Standards This unit conforms to the following standards: EN55032:2015 (Class A)
  • Page 15: Emc Performance Of Cables And Connectors

    SFP+ type ports; and fit 75 Ώ RF terminators to BNC type ports COAXIAL CABLES Coaxial cables connections (particularly serial digital video connections) shall be made with high-quality double-screened coaxial cables such as Belden 8281 or BBC type PSF1/2M and Belden 1694A (for 3Gbps). D-TYPE CONNECTORS D-type connectors shall have metal shells making good RF contact with the cable screen.
  • Page 16 Notices...
  • Page 17: Table Of Contents

    2.2 MV-800-RP Multiviewer Rear Panel (1312) ........15 Issue 2 Revision 1 Page xvii © 2019 Grass Valley, a Belden Brand...
  • Page 18 Contact Us Corporate Head Office ..........53 Issue 2 Revision 1 Page xviii © 2019 Grass Valley, a Belden Brand...
  • Page 19: Product Overview

    One or more can be added into any existing Sirius 800 router. The MV-800 is available from Grass Valley, a Belden brand, as an option on a new Sirius 800 router from the factory or as an option to be installed in the field. A single MV-800 can drive up to 12 multiviewer display monitors.
  • Page 20: Integrated Multiviewer Benefits

    • More than one MV-800 per router, see Table 1. Table 1 MV-800 in Sirius 800 series routers Sirius 800 Router Maximum number of MV-800’s Sirius 830 2-off Sirius 840 3-off Sirius 850 2-off Issue 2 Revision 1 Page 2 © 2019 Grass Valley, a Belden Brand...
  • Page 21 IP. • MV-800 input video streams can be viewed on a desktop PC with appropriate software. See the ‘MV-8 Series Multiviewer’ user manual. Issue 2 Revision 1 Page 3 © 2019 Grass Valley, a Belden Brand...
  • Page 22: Integration Into Sirius 800 Routers

    Thus, the addition of an MV-800 Integrated Multiviewer into a Sirius router retains the router’s: • Main outputs. • Main Crosspoint redundancy. • Processing capability on all router inputs and outputs. Issue 2 Revision 1 Page 4 © 2019 Grass Valley, a Belden Brand...
  • Page 23: Mv-800 Main Input And Output Connections

    4K-capable outputs via quad-link 3G-SDI. Figure 3 MV-800 Main Input and Output Connections For more detailed information about external connections to MV-800, see Section 2 “MV-800 Hardware Modules”. Issue 2 Revision 1 Page 5 © 2019 Grass Valley, a Belden Brand...
  • Page 24: Mv-800 Components

    How many MV-800’s are being fitted to the router. The list of front modules, rear panels etc. required for an MV-800 installation is given in Table 2. Issue 2 Revision 1 Page 6 © 2019 Grass Valley, a Belden Brand...
  • Page 25 Up to 4-off: SFP blanking plugs. SFP type: • CC-TTH-3G-N (SDI). • ST31ST31-3 (Fiber). • FC1-HDMI2 (HDMI). • SFPBLANK. MV-800 Hardware Installation, on page 21 for hardware installation instructions. Issue 2 Revision 1 Page 7 © 2019 Grass Valley, a Belden Brand...
  • Page 26: Order Codes

    MV-800 Desktop Multiviewer.  MV-800-DT This is a license option code to enable display of streaming IP sources from an MV800 on a desktop multiviewer. One license per seat. Issue 2 Revision 1 Page 8 © 2019 Grass Valley, a Belden Brand...
  • Page 27: Multiviewer Terminology

    Initial configuration and set up of the MV-800 multiviewer is done via Grass Valley’s RollCall Control Panel application. See the‘MV-8 Series Multiviewer’ user manual, in the section about RollCall templates and “Getting Started”. Issue 2 Revision 1 Page 9 © 2019 Grass Valley, a Belden Brand...
  • Page 28: Configuration Screens (Rollcall Templates)

    MV-8X0 multiviewer units. It can show the same video wall as an MV-8X0 Multiviewer unit or it can show a different video wall layout. See the ‘MV-8 Series Multiviewer’ user manual for more information. Issue 2 Revision 1 Page 10 © 2019 Grass Valley, a Belden Brand...
  • Page 29: Mv-800 Hardware Modules

    The 5902 module is described in the Sirius 800 User Manual. CAUTION Electrostatic Damage Static precautions must be observed when handling, inserting or removing modules. Issue 2 Revision 1 Page 11 © 2019 Grass Valley, a Belden Brand...
  • Page 30: Mv-800 Multiviewer Front Module (5934)

    Figure 5 for LED details Note: Module’s main component side is shown, which is upper-most in the router frame. Figure 4 MV-800 Integrated Multiviewer Module (5934) Issue 2 Revision 1 Page 12 © 2019 Grass Valley, a Belden Brand...
  • Page 31: Front Module Status Led Indicators

    On: Hardware fault detected. Contact Grass Valley Customer Support  (Grass Valley Technical Support on page 53 for contact details). Table 4 5934 MV-800 Integrated Multiviewer Module LED Information Issue 2 Revision 1 Page 13 © 2019 Grass Valley, a Belden Brand...
  • Page 32: Dip Switches

    2.1.3 Engineering connectors There are two other connectors on the front edge of the module, see Figure 5. These are for Engineering use only and should not be used. Issue 2 Revision 1 Page 14 © 2019 Grass Valley, a Belden Brand...
  • Page 33: Mv-800-Rp Multiviewer Rear Panel (1312)

    There are up to 12 multiviewer display outputs from the MV-800: • 2 outputs per SDI coax or fiber SFP video module. • 1 output per HDMI SFP video module. Issue 2 Revision 1 Page 15 © 2019 Grass Valley, a Belden Brand...
  • Page 34: Connectors

    10G Ethernet Ports 3 and 4 2-off 10 Gbps, SFP+ Ethernet sockets, RJ45 (10G network interfaces. Not used.) Note 1: SFP blanking plugs must be fitted if no SFP is present. Issue 2 Revision 1 Page 16 © 2019 Grass Valley, a Belden Brand...
  • Page 35: Rear Panel Leds

    Licensed Output; SFP Fitted. 720p video output signal. Flashes Green/White at 1Hz.  Green / White Flashing ..Licensed Output; SFP fitted. 720p with embedded audio. Licensed Output; No SFP Fitted. Issue 2 Revision 1 Page 17 © 2019 Grass Valley, a Belden Brand...
  • Page 36: 2Ethernet Outputs

    Ethernet Port Status LEDs Color LEDs Status Green / Off Ethernet link established Green Solid / Flashing Activity on Ethernet link Off / Off Establishing link, or unconnected. Issue 2 Revision 1 Page 18 © 2019 Grass Valley, a Belden Brand...
  • Page 37: Ltc And Gpio Connector Pin-Outs

    Note: MV-800 GPI inputs - Inputs have weak internal pull-down resistors. • Can be driven by input voltages of up to +5 V. • A logic “low” input is represented by an input voltage below +0.8 V. Issue 2 Revision 1 Page 19 © 2019 Grass Valley, a Belden Brand...
  • Page 38: Example: Driving Leds From The Gpi Outputs

    LED 4 Pin 25 GPI Out 4 Figure 9 Connecting LEDs to GPI Outputs CAUTION Electrostatic Damage Static precautions must be observed when inserting and removing cards. Issue 2 Revision 1 Page 20 © 2019 Grass Valley, a Belden Brand...
  • Page 39: Mv-800 Hardware Installation

    The following sections describe these installation steps. More than one MV-800 unit may be fitted to a Sirius router and these instructions cover the fitting of one or more units. Issue 2 Revision 1 Page 21 © 2019 Grass Valley, a Belden Brand...
  • Page 40: Initial Checks And Actions

    • See Sirius 800 User Manual for router power requirements. • See Appendix A MV-800 Specification, on page 47 for MV-800 Integrated Multiviewer power requirements. • Contact Grass Valley support for advice. Issue 2 Revision 1 Page 22 © 2019 Grass Valley, a Belden Brand...
  • Page 41: Fitting Of Video Sfps To Mv-800 Rear Panel

    Before inserting the SFP modules, take notice of the required SFP orientation for fitting into the SFP cages of the MV-800 Rear Panel, as shown in Figure 12. Issue 2 Revision 1 Page 23 © 2019 Grass Valley, a Belden Brand...
  • Page 42 SFP module removal, if required, is achieved by operating a small lever or lever-bar on the SFP module before sliding the SFP video module out of its cage. Issue 2 Revision 1 Page 24 © 2019 Grass Valley, a Belden Brand...
  • Page 43: Identifying Modules And Slots In Router

    Main Crosspoint module 2-off half-width Audio Crosspoints slots + 2-off full-width Video Crosspoints. Above vertical Sirius 840 Input module slots Above vertical Sirius 850 Input module slots Issue 2 Revision 1 Page 25 © 2019 Grass Valley, a Belden Brand...
  • Page 44 Sirius 840 Sirius 830  Figure 14 Sirius 800 sections of the router frame for MV-800 option installation, a) front Multiviewer Fan Doors and b) Rear Panel Section Issue 2 Revision 1 Page 26 © 2019 Grass Valley, a Belden Brand...
  • Page 45 IMPORTANT Only open router fan doors for less than 2 minutes and ensure they are fully closed afterwards. This ensures continued cooling of the router. Issue 2 Revision 1 Page 27 © 2019 Grass Valley, a Belden Brand...
  • Page 46 (2) 1312, MV-800 Rear Panel 5902 Multiviewer Crosspoint Module Possible second MV-800. Otherwise, fit Blanking Rear Panel. Figure 15 Sirius 830 - Relevant Module Positions for MV-800 modules Issue 2 Revision 1 Page 28 © 2019 Grass Valley, a Belden Brand...
  • Page 47 * Possible second MV-800, otherwise fit a Blanking Rear Panel. ** Possible third MV-800, otherwise fit a Blanking Rear Panel. Figure 16 Sirius 840 - Relevant Module Positions for MV-800 modules Issue 2 Revision 1 Page 29 © 2019 Grass Valley, a Belden Brand...
  • Page 48 (2) 1312 MV-800 Rear Panel 5902 Multiviewer Crosspoint Module Possible second MV-800, or fit a Blanking Rear Panel. Figure 17 Sirius 850 - Relevant Module Positions for MV-800 modules Issue 2 Revision 1 Page 30 © 2019 Grass Valley, a Belden Brand...
  • Page 49 Step 4. The types of modules that are required for your MV-800 installation are listed in the right-hand side columns of the record sheet in Table 10, in the columns headed “After fitting MV-800” Issue 2 Revision 1 Page 31 © 2019 Grass Valley, a Belden Brand...
  • Page 50 For any other possible combination of modules, please contact Grass Valley support. Note: When completed, Table 10 will indicate which modules need to be removed for MV-800 installation. Issue 2 Revision 1 Page 32 © 2019 Grass Valley, a Belden Brand...
  • Page 51: Removal And Then Fitting Of Modules

    Table 10 gives the before and after module configuration. Read through the following installation steps and notes to ensure that you understand them before installing the MV-800 option. Issue 2 Revision 1 Page 33 © 2019 Grass Valley, a Belden Brand...
  • Page 52: Module Removal Procedure

    Rear module removal: Remove all rear modules for slots that need to be emptied. Unscrew two rear panel securing screws on each module; then remove the module. Issue 2 Revision 1 Page 34 © 2019 Grass Valley, a Belden Brand...
  • Page 53: Fitting Preliminaries

    Static precautions must be observed when handling, inserting or removing modules. Note: Rear module fitting requires: • A Pozidriv screwdriver • Two pan head, M3 x 6 mm, zinc plated screws per rear module. Issue 2 Revision 1 Page 35 © 2019 Grass Valley, a Belden Brand...
  • Page 54 Thus, Slot (1) refers to the slot labeled (1) in the figures, etc Refer to Table 10 on page 32, this shows which modules may be fitted. Issue 2 Revision 1 Page 36 © 2019 Grass Valley, a Belden Brand...
  • Page 55: Module Fitting Procedure

    Fasten the two rear plate-securing screws. Gently tighten. Do not over-tighten. IMPORTANT The risk of non-compliance and overheating is with the user if blanking plates are not fitted in unused rear slots. Issue 2 Revision 1 Page 37 © 2019 Grass Valley, a Belden Brand...
  • Page 56 11. Close and secure the front fan door assembly, making sure not to trap any wires. 12. Close and lock the router front door. The MV-800 Integrated Multiviewer hardware is now installed in the router frame. Issue 2 Revision 1 Page 38 © 2019 Grass Valley, a Belden Brand...
  • Page 57: Connecting Cables

    This means the MV-800 can still appear to be operating normally, i.e. with all Ethernet ports connected, even with one or more unconnected network ports. There is a MV-800 performance penalty for operating in this way. Issue 2 Revision 1 Page 39 © 2019 Grass Valley, a Belden Brand...
  • Page 58: Mv-800 Module Booting

    Note: Use the ‘1G1’ network interface when performing the initial unit configuration with Grass Valley RollCall control panel. Note: The ‘Eng’ interface is a reserved internal IP network interface, do not use this interface. Issue 2 Revision 1 Page 40 © 2019 Grass Valley, a Belden Brand...
  • Page 59: Sirius 800 Router Configuration

    Using Grass Valley Workbench, Pull the router’s configuration from the router, modify it and Push it back to the router. Contact Grass Valley support for help and advice. Issue 2 Revision 1 Page 41 © 2019 Grass Valley, a Belden Brand...
  • Page 60: Matrix Output Ports

    However, for a third, ‘upper-slot’ MV-800 module (i.e. top slot in router frame), only 44 inputs are available to the MV-800 Integrated Multiviewer.  This is reflected in Table 11. Issue 2 Revision 1 Page 42 © 2019 Grass Valley, a Belden Brand...
  • Page 61: Module Configuration

    • Figure 24 and Figure 25 for Sirius 830, • Figure 26 and Figure 27 for Sirius 840, • Figure 28 and Figure 29 for Sirius 850. Issue 2 Revision 1 Page 43 © 2019 Grass Valley, a Belden Brand...
  • Page 62 MV-800 User Manual Sirius 800 Router Configuration 4.2 Rear of Router Frame Front of Router Frame Figure 24 Sirius 830 Modules Figure 25 Sirius 830 Module Addresses Issue 2 Revision 1 Page 44 © 2019 Grass Valley, a Belden Brand...
  • Page 63 Sirius 800 Router Configuration 4.2 Rear of Router Frame Front of Router Frame Figure 26 Sirius 840 Modules Front of Router Frame Figure 27 Sirius 840 Module Addresses Issue 2 Revision 1 Page 45 © 2019 Grass Valley, a Belden Brand...
  • Page 64 MV-800 User Manual Sirius 800 Router Configuration 4.2 Rear of Router Frame Front of Router Frame Figure 28 Sirius 850 Modules Figure 29 Sirius 850 Module Addresses Issue 2 Revision 1 Page 46 © 2019 Grass Valley, a Belden Brand...
  • Page 65: Appendix A Mv-800 Specification

    (For router destination number mapping, see Table 11 on page 42.) Note: There are only 44 inputs available to an MV-800 fitted into the upper slot of a Sirius 840 router frame. Issue 2 Revision 1 Page 47 © 2019 Grass Valley, a Belden Brand...
  • Page 66: Head Display Outputs

    Single HDMI SFPs. (Up to 6 x HDMI outputs, 1080p). Display Output Delay Progressive input: 1 input frame + 1 to 3 output frames. Interlaced input: 1 input fields + 1 to 3 output frames. Issue 2 Revision 1 Page 48 © 2019 Grass Valley, a Belden Brand...
  • Page 67: Input Video Standards

    720p 60Hz (ANSI/SMPTE-296M(1)-292M(L)) 720p 59.94Hz (ANSI/SMPTE-296M(2)-292M(M)) 720p 50Hz (ANSI/SMPTE-296M(2)-292M(M)) SD Video Standards 525 60Hz/ (ITU-R BT.601-5, ANSI/SMPTE-259M(2)   59.94Hz 4:3/16:9 50Hz (ITU-R BT.601-5, ANSI/SMPTE-259M(2) 4:3/16:9  Issue 2 Revision 1 Page 49 © 2019 Grass Valley, a Belden Brand...
  • Page 68: Ip Outputs

    2 x 1 Gbps SFP+ cages for Ethernet SFPs. Ethernet socket RJ45. 10G Ethernet 2 x 10 Gbps SFP+ cages for Ethernet SFPs. Ethernet socket RJ45. Interfaces are not used. Issue 2 Revision 1 Page 50 © 2019 Grass Valley, a Belden Brand...
  • Page 69: Monitoring And Alarms

    3.0.10 or later MV-8 Series Multiviewer 3.0.13 or later Note: For future releases: Please refer to Multiviewer, Orbit and RollCall Control Panel etc. software release notes for compatibility information. Issue 2 Revision 1 Page 51 © 2019 Grass Valley, a Belden Brand...
  • Page 70 MV-800 User Manual User Notes: Issue 2 Revision 1 Page 52 © 2019 Grass Valley, a Belden Brand...
  • Page 71: Contact Us

    Corporate Head Office Grass Valley 3499 Douglas-B.-Floreani St-Laurent, Quebec H4S 2C6 Canada Telephone:+1 514 333 1772 Fax:+1 514 333 9828 www.grassvalley.com Issue 2 Revision 1 Page 53 © 2019 Grass Valley, a Belden Brand...

This manual is also suitable for:

Grass valley mv-800-rp59341312

Table of Contents