2 Description
2 Description
6
The ESR5-BWS-31-24VAC-DC safety relay can be used to monitor electro-
sensitive protective equipment with monitored active switching out-
put (OSSD) in accordance with EN 61496 as well as emergency stop and
safety door locking mechanisms.
Depending on the external wiring, up to category 4, PL e according to
EN ISO 13849-1 or SILCL 3 according to EN 62061 can be achieved.
The safety relay is equipped with three enabling current paths that drop out
without delay corresponding to stop category 0 according to EN 60204-1.
Features
•
Emergency stop and safety door monitoring
•
Light grid monitoring
•
Suitable up to category 4, PL e (EN ISO 13849-1), SILCL 3 (EN 62061)
•
Single or two channel operation
•
3 undelayed enabling current paths
•
1 undelayed signaling current path
•
Plug-in screw terminal blocks
ESR5-BWS-31-24VAC-DC 12/19 MN049005EN www.eaton.com