Rs-485 Interface (Ls1Xx*, Ls2Xx*); Electrical Connection And Data Cables - Pepperl+Fuchs WCS Series Manual

Read head position encoding system electrical data
Hide thumbs Also See for WCS Series:
Table of Contents

Advertisement

WCS* Read Head Position Encoding System

RS-485 Interface (LS1xx*, LS2xx*)

4
RS-485 Interface (LS1xx*, LS2xx*)
The serial interface of the read head allows the position values and other defined operating
data to be read out.
Up to four WCS2B and/or WCS3B read heads can be interconnected in one RS-485 bus line.
In this case, the read heads must have different addresses. The read head address must be
configured in the read head if it has not already been set. If the read head address is already
preset, this is indicated by the type designation of the read head. In the section "Type Overview
of WCS Read Head," you will find a detailed breakdown of the read head types, see chapter
10.
4.1

Electrical Connection and Data Cables

Caution!
Property damage and system malfunctions due to incorrect pinout
Incorrect assignment of the wire pairs to the respective pins can result in property damage and
system malfunctions.
Note the assignment of the wire pairs to the pins as shown in the respective wiring dia-
grams.
Connection diagram for WCS2B read head
The WCS2B read head is connected via a 5-pin M12 plug.
(intern)
Figure 4.1
Connection diagram for WCS3B read head
The WCS3B read head is connected via a 5-pin M12 plug.
(intern)
Figure 4.2
16
WCS2B-LS
2
3
220Ω
390Ω
390Ω
5 V
S2
4
1
WCS2B-LS2...
S2 = ON
WCS2B-LS1...
S2 = OFF
WCS2B, RS-485 interface
WCS3B-LS
1
3
220Ω
390Ω
390Ω
5 V
S2
2
4
5
WCS3B-LS2...
S2 = ON
WCS3B-LS1...
S2 = OFF
WCS3B, RS-485 interface
UB 10 ... 30 V
GND
RS485+
RS485-
UB 10 ... 30 V
GND
RS485+
RS485-
Velocity output *)
I
= max. 150 mA
out
*) only with Option S, velocity output
1
5
2
4
3
1
5
2
4
3