1. Unscrew and remove the four M6 bolts (Bolt B) from housing base (see Figure 5),
2. Hold the CIMS Mk IV upside down (sensor surface upward), make sure the four M6 bolts
(Bolt A) are lying loose in the intermediate piece (see Figure 5), so they do not block the
rotation.
3. Rotate the housing base with respect to the intermediate piece in the desired position
(maximum angle of rotation 270). If necessary, two hexagon socket screw keys can be
used with the holes in CIMS Mk IV, see Figure 6.
4. Mount the four M6 bolts (Bolt B) in the intermediate piece (7.5Nm).
Figure 4: CIMS Mk IV housing assembly component
names.
Figure 6: Holes of hexagon socket screw keys.
F 037 300 069 (2013.05.21)
Bolt A (4x)
(countersunk)
Cover
Intermediate
piece
Housing
base
Adapter
ring
Figure 5: Remove screws.
15
Bolt B (4x)
Bolt A (4x)