Gravity Conversion; Battery Terminal Connections - Isuzu 4BG1 Instruction Manual

1999 model year
Table of Contents

Advertisement

NOTICE:
The battery
electrolyte
is dilute sulfuric acid. So, be careful
r
.
not to stain your body and clothes with it. If stained,
rinse
portion
in clean water.
Gravity
conversion
The specified
electrolyte
temperature
for the gravity
measure-
ment is 20°C (68°F).
Measure
the electrolyte
temperature
and do the conversion
in
accordance
with the following
formula
when
the temperature
does not fall to the specified
temperature.
30
= St + 0.0007
(t -20)
S20 ; gravity at 20°C
St ; gravity
measured
t ; electrolyte
temperature
whe measured
Battery
terminal
connections
Periodically,
check. the battery
terminals
for loose
connection
and corrosion.
For
the
check
interval,
follow
the
machine
manufacturer' s
standard.
Loose connection
will cause
hard engine
starting
or
deficient
battery charging.
If the terminals
are excessively
corroded,
disconnect
the battery
cables and polish them with a wire brush or sandpaper.
Never
reverse the "+" and "-" terminals
when
reconnecting
the
cables. Even a short period of reverse connection
could damage
the electrical
parts.
67