NOTE: Normally, the Pinch Tube Assy. (7) will provide 100,000 to 200,000 plus On/Off actions before
requiring replacement. When this is necessary, refer to detailed instructions “1212 Pinch Tube Assembly
Replacement”. (Refer to page 16)
The TS1251 Pressure Dispenser with optional TS1212 Dispensing Valve is now ready for use.
WARNING:
Cyanoacrylate Adhesives are severe eye irritants and skin bonders. Immediate bonding
of eyes, skin or mouth may occur upon contact. These adhesives may cause permanent eye damage.

5.0 ADHESIVE SUPPLY REPLACEMENT

WARNING: AVOID SPILLING THESE MATERIALS ON SKIN. INSTANT BONDING WILL OCCUR. EYE
PROTECTION REQUIRED.
NOTE: Adhesive may be stored in unused adhesive dispenser for up 72 hours. If unused for more than 72
hours, dispenser should be cleaned and adhesive removed.
1. Close Air Pressure Regulator Knob (8), turn counter clockwise and lower air pressure to zero.
WARNING: Do not open lid until air pressure is at zero.
2. Disconnect air supply line if necessary, do not open Lid until pressure is zero.
3. Hold dispensing device (i.e. TS 1201 Pen or TS1212 Shot Valve) higher than pressure reservoir, activate device
[for Pen (13) Press Trigger handle, or for Valve (14) apply air pressure to Piston]. Adhesive must drain back into
adhesive bottle.
4. Loosen Lid Knob (7) slowly. If excessive effort is required, make sure air pressure is zero.
5. Open Lid slowly.
6. To remove old Dip Tube (Refer to figure 1).
a. Remove Dip Tube (12) form Luer Fitting (11) inside pressure reservoir. When loosening Dip Tube Fitting
support tube to allow for twisting to be absorbed in fingers and not allow Tube to flail out of Bottle.
b. Drop used Dip Tube into empty adhesive bottle.
c. Remove empty adhesive bottle from pressure reservoir and discard properly.
7. Install new Dip Tube. Refer to Section 4.0 Set Up and Installation Notes 5 & 6 (See figure 1).
CAUTION: Never pour adhesives directly into pressure pot.
AVOID SPILLING THESE MATERIALS ON SKIN.
INSTANT BONDING WILL OCCUR. DO NOT POINT
NEEDLE IN DIRECTION OF YOU OR OTHERS
Page 12
FIGURE 7