Electrical connection of the unit
Safety
ATTENTION
All work must be carried out by qualified persons and in compliance with existing legislation and
regulations.
ATTENTION
It is important that the power is off, if you do work to the electrical components of the unit.
It is important to check that wires are not damaged or squeezed during connection and use.
Compact P AIR
Heat pump, internal AIR unit
One electrical connection
for the whole unit
3 x 400, N, Ground, 16A
Safety switch
Compact P / Compact P Polar - AIR "RS" (English)
Heat pump, external AIR unit
230V 50Hz 16A
Safety switch
20m communications cable
with plug connector for internal unit
Power connection for Compact P, ventilation and hot water
This power connection via Schuko socket allows to measure the
power consumption of the ventilation separately, as well as the
possibility that the hot water part does not have the same
connection as the heat pump.
BY NILAN