Insulation of hoses from the outdoor unit

It is important that the brine hoses between the indoor part and the outdoor part are well insulated,
according to current standards. This is done to avoid heat loss and to achieve good operation.
CAUTION
If the brine hoses is not well insulated, the AIR heat pump will use significantly more energy and
in worst case, there will not be enough heat in the house.

Check list for the central heating system prior to start-up

The check list is used when starting and delivering the system, and it should always be filled in. See the
other sections in the manual for further information.
Electrical connection and controls
The power supply is connected and secured in
accordance with the wiring diagram and manual
The control panel is installed in a place that can easily
be seen by the user
Central heating circuit
The central heating circuit is sealed
The central heating circuit has been vented after filling
Central heating circuit pressure, overpressure
The opening pressure for the central heating circuit's
safety valve is correct
The circulation pump is rated correctly for the
installation
The circulation pump is in constant operation or is
controlled by the heating pump
Compact P / Compact P Polar - AIR "RS" (English)
Checked - date
Checked - date
Notes
Notes
BY NILAN
Bar
47