Robofon (Message Type J) - Bosch Conettix D6600 Manual

Computer interface of receiver/gateway
Table of Contents

Advertisement

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
Table 70: RB2000 (Message Type R) Printer Output
Characters
MM/DDsHH:MM
RB2
Lxx
ACCT
xxxxxxxxxxxx
RB2000_EVENT_R
AW_DATA
RB2000_EVENT_R
AW_DATA1
RB2000_EVENT_R
AW_DATA 2
RB2000_EVENT_R
AW_DATA n

3.2.17 Robofon (Message Type j)

Robofon
SIA Mode Description
Example
<LF><CRC><j><sequence#><receiver#><line#>[#aaaaaa|EE]<CR>
Table 71: Robofon (Message Type j) Byte Description
Title
LF
CRC
Message Type
sequence#
receiver#
line#
(Line/Group #)
account #
EE
62
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
Description
Date and time.
RB2000 format.
Line number.
Subscriber number, up to 12 characters(hex).
The raw data of RB2000 event.
The raw data of RB2000 event 1.
The raw data of RB2000 event 2.
The raw data of RB2000 event n.
Description
Standard line feed character.
Cyclical redundancy check number.
j
The message sequence number. The valid sequence number range is 0001
to 9999.
The receiver gateway that sent the message. Valid digits are 01 to 99 for
D6600/D6100/D6100IPv6.
The line number of the line in the receiver gateway that sent the message.
Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal
messages.
The communicator's account number has up to six digits.
Event code.