Summary of Contents for Avalue Technology OFT-1202
Page 1
OFT-1202/1502 12.1"/15" Open Frame Tablet Quick Reference Guide Ed –05 July 2017 Copyright Notice Copyright 2017 Avalue Technology Inc., ALL RIGHTS RESERVED. Part No. E2017OT12A0R...
Page 2
(2) Use only shielded cables to connect I/O devices to this equipment. (3) Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. 2 OFT-1202/1502 Quick Reference Guide...
Page 3
RF exposure compliance, in order to comply with RF exposure limits established in the ANSI C95.1 standards, the distance between the antennas and the user should not be less than 20 cm. OFT-1202/1502 Quick Reference Guide...
Page 4
“CAUTION - Use a power cord that matches the voltage of the power outlet, which has been approved and complies with the safety standard of your particular country.” “WARNING – To avoid risk of electric shock, this equipment must only be connected to a supply mains with protective earth.” 4 OFT-1202/1502 Quick Reference Guide...
Place all electronic components in a static-dissipative surface or static-shielded bag when they are not in the chassis. 1.2 Packing List 1 x OFT-1202/1502 Open Frame Tablet 1 x ACC-ADP-060N-04R AC/DC adapter 12V/5A ...
EETI Res. Touch controller External I/O Serial Port DSUB-9 x1 1 x USB 2.0 Type A USB Port 1 x Micro USB2.0 client (reserved) Video Port 1 x HDMI LAN Port 1 x 10/100/1000 Ethernet Others Avalue IET module: OFT-1202/1502 Quick Reference Guide...
Page 10
Random Vibration Operation Reference IEC60068-2-64 Testing procedures Test Fh : Vibration boardband random Test 1. PSD: 0.00454G²/Hz , 1.5 Grms 2. Operation mode 3. Test Frequency : 5-500Hz 4. Test Axis : X,Y and Z axis 10 OFT-1202/1502 Quick Reference Guide...
Page 11
4. No. of Shock:Z axis 300 times 5. Test Axis: Z axis 6. Operation mode Operating 0°C ~ 40°C Temperature Operating 0% ~ 90% relative humidity, non-condensing Humidity Storage -20°C ~ 60°C Temperature Note: Specifications are subject to change without notice. OFT-1202/1502 Quick Reference Guide 11...
Quick Reference Guide 2. Hardware Configuration For advanced information, please refer to: 1- ACP-Z8300 included in this manual. Note: If you need more information, please visit our website: http://www.avalue.com.tw OFT-1202/1502 Quick Reference Guide 17...
40 x 2 wafer, pitch 0.80mm JB2B1 IET connector Serial port 1 connector 5 x 2 wafer, pitch 2.00mm COM1 COM2 Serial port 2 connector JMCU1 MCU Firmware upgrade connector 5 x 1 header, pitch 2.00 mm OFT-1202/1502 Quick Reference Guide 19...
10 Mbits/sec data rate is selected Data Rate Yellow LED on 100 Mbits/sec data rate is selected LAN link is not established Link/ACT Green LED on LAN link is established LED Blinking LAN active is occurring 20 OFT-1202/1502 Quick Reference Guide...
2.4.16 Audio connector (JAUDIO1) Signal PIN PIN Signal HP_R_CN HP_L_CN Don’t Use Don’t Use IN1N_MIC_R IN1P_MIC_R HP_JD HP_JD Note: HP_JD enable Headphone and Microphone function at the same time. 2.4.17 MCU connector (JMCU1) Signal MCU_MCLR MCU_ICSPCLK MCU_ICSPDAT OFT-1202/1502 Quick Reference Guide 29...
Warning: Risk of Explosion if Battery is replaced by an Incorrect Type. Dispose of Used Batteries According to the Instructions." Attention: Risque d'explosion si la batterie est remplacée par un type incorrect. Jetez les piles usagées selon les instructions. 32 OFT-1202/1502 Quick Reference Guide...
IC: 6317A-RTL8723BS FCC ID is located on the MB WiFi Module: Remove all screws on back cover. WiFi Module is located on MB underneath of the back cover. FCC ID is shown on WiFi Module. OFT-1202/1502 Quick Reference Guide 33...
OFT-1202/1502 3. Software Configuration Note: If you need more information, please visit our website: http://www.avalue.com.tw 34 OFT-1202/1502 Quick Reference Guide...
Quick Reference Guide 3.1 HDMI Monitor/Touch Calibration on Windows The Windows 10 IoT image included in OFT-1202 and OFT-1502 is HDMI Monitor pre-calibrated. If you would like to run Windows installation process for any reason, you will need to run Monitor/Touch calibration when your HDMI monitor is connected to OFT-1202 and OFT-1502 at the first time.
Page 36
OFT-1202/1502 3. Select Hardware and Sound 4. Select Calibrate the screen for Pen or touch input 36 OFT-1202/1502 Quick Reference Guide...
Page 37
Quick Reference Guide 5. Under Configure click on Setup 6. Click the screen with the touch Sensor, and then the OS will know how to follow the finger on which Display OFT-1202/1502 Quick Reference Guide 37...
Page 38
OFT-1202/1502 7. Use keyboard and press Enter when calibration message is shown on your HDMI Monitor. 8. Calibration is done. 38 OFT-1202/1502 Quick Reference Guide...