Test Mode

Test Mode has been integrated into this product to improve end-of-line testing during production and can be used
to isolate components for individual function testing. Test mode should be conducted by trained personnel only.
The icons on the On Board Control buttons (Figure 1) do not match the commands they are associated with,
when in test mode.
1. Ensure unit is connected to power and water is supplied.
2. Remove logs or top plate and set aside.
3. Press power switch on (Figure 1A). Presence of power will be indicated by one beep
4. Press the troubleshooting button
5. Press the following buttons to test functionality of listed components - press once will turn On and press
again to turn off
6. After 15 seconds of inactivity the unit will beep and then return to regular Standby mode, or the On/Off
button can be switched to Off to end the test mode.
REV
PCN
DATE
00
-
21-12-15
01
-
31-07-19
02
-
07-10-19
03
-
08-07-20
1-888-346-7539 | www.dimplex.com
In keeping with our policy of continuous product improvement,
we reserve the right to make changes without notice.
© 2020 Glen Dimplex Americas
18
(Figure 1D) on the side that the testing is required, unit will beep.
Component Test
Expected Functionality
LED Assembly /
Lights turn on
LED Driver
Crackling sound turns on
Sound
Fan turns on
Fan
Transducer will turns on and bubbling will be seen
Transducer
Solenoids will turn On (the main solenoid coming in and
Solenoids
Relays will be activated to turn the heating element on,
Heater Relay
LEDs in log set will turn on (if present)
Log Set
coming out of the transducer
the solenoid on the side being tested). The sound
of the solenoids can be heard (a slight thump), and
possibly the sound of water flowing.
a quiet clicking noise can be heard. The element will
get warm.