Dimplex CDFI1000P Service Manual page 16

Hide thumbs Also See for CDFI1000P:
Table of Contents

Advertisement

Unit continuously blinks
2.4
four times
SECTION
PROBLEM
3 .0
Flame
The flame effect has too
3.1
much smoke or is coming
out too fast
Mist is not coming out
3.2
evenly
The flame effect is too
3.3
low
Flame appears to be roll-
3.4
ing back into the unit
Mist is being produced
under the top cover, but
3.5
does not rise to create a
flame effect
16
Water is refilling too slowly
CAUSE
Flame effect control is set too high
Filter is missing off of fan housing
Condensation building up on the mist
outlet
Unit is not level
Media is blocking air flow
The transducer is not operating correctly
- put the unit in test mode to test the
transducer
If using demineralized water, unit will not
produce a consistent mist
Water in unit is too cold
Flame effect control is set too low
Insufficient air intake
Transducer is defective
Flame is not rising
Insufficient air intake
The heating element is not operating
correctly- put unit in test mode to test the
operation of the heating element
Cord is located over emitter on trans-
ducer
Transducer is not installed correctly
Water in fan duct
Fan is not operating correctly - put unit in
test mode to test the fan
Turn unit off with the main power switch. Wait 60
seconds before turning back on.
If problem persists, clean water filter and inspect
plumbing to make sure pressure is adequate
and nothing is obstructing water flow.
SOLUTION
Adjust the flame height on both the secondary
and/or primary controls
Insert fan filter
Remove the build up of condensation
Adjust the feet under the unit to ensure that the
unit has been installed level, front to back and
side to side
Rearrange media to ensure mist outlet is not
being blocked
If the transducer is running, ensure that the
emitter is clean and free of calcium deposits or
scaling
If the transducer is not running, replace the
transducer with the provided additional transducer
Add 1/8 tsp of table salt to water reservoir to
introduce electrolytes, only repeat when mist is
not being produced correctly
Allow water to warm to room temperature.
Adjust the flame height on both the secondary
and/or primary controls
Enlarge area for air to enter unit in such a way
that it will reach the bottom. Refer to to installa-
tion guide for requirements.
Replace transducer
Refer to section 3.5
Enlarge area for air to enter unit in such a way
that it will reach the bottom. Refer to to installa-
tion guide for requirements.
If no click is heard from the relay, replace the
main board
If a click can be heard, but the element does not
get warm, replace the heating element
Relocate cord so that mist is free to rise off of
transducer
Ensure that the connection has clicked into
place, and that transducer is seated correctly
Ensure there is no water in the duct that blows
air up to the flame
Ensure fan filter is clean and dry
If fan is not working in test mode, replace fan. If
issue persists, replace main board
www.dimplex.com

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents