Download Print this page

Advertisement

Quick Links

Advantage
Model 4200
INSTRUCTIONS
parts lists
constant flow respirator
This booklet, including the warnings and cautions inside, must be
carefully read and followed by all persons who use or maintain
this product, including those who have any responsibility involv-
ing its selection, application, service or repair. This respirator will
perform as designed only if used and maintained according to
the instructions. Otherwise, it could fail to perform as designed
and persons who rely on this product could sustain serious per-
sonal injury or death.
The warranties made by MSA with respect to the product are void-
ed if the product is not installed, used, and serviced in accordance
with the instructions in this manual. Please protect yourself and
your employees by following the instructions. Please read and
observe the WARNINGS and CAUTIONS inside. For any additional
information relative to use or repair, write or call 1-800-MSA-2222
during regular working hours.
See separate insert for NIOSH approval information for the Duo-
Twin Respirator P/N 10091607.
TAL 018 (L) Rev. 1
WARNING
© MSA 2010
®
Prnt. Spec. 10000005389
4000
Mat. 10089926
Doc. 10089926

Advertisement

loading
Need help?

Need help?

Do you have a question about the Advantage 4000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MSA Advantage 4000

  • Page 1 The warranties made by MSA with respect to the product are void- ed if the product is not installed, used, and serviced in accordance with the instructions in this manual. Please protect yourself and your employees by following the instructions.
  • Page 2 TABLE OF CONTENTS NIOSH APPROVAL INFORMATION. 2 AFTER USE ....10 Cautions and Limitations ..2 FITTING THE MASK.
  • Page 3 SPECIAL USER INSTRUCTIONS 1. Mersorb and Mersorb-P100 cartridges can be used against a mixture of chlorine and mercury that are both present simultaneously, but cannot be used if alternating between mercury-contaminated atmospheres and chlorine-contaminated atmospheres. 2. Mersorb and Mersorb-100 respirators utilize an end-of-service-life indica- tor for use against metallic mercury vapor.
  • Page 4 RESPIRATOR USE LIMITATIONS The wearer must comply with the following MSA respirator use limitations: A. Maximum Use Concentration Do not exceed ANY of the applicable maximum use concentrations listed below: RESPIRATOR RESPIRATORS WITH RESPIRATORS WITH TYPE PARTICULATE FILTERS CHEMICAL OR COM-...
  • Page 5 95% or (b) that the total mass loading of the filter is less than 100mg.] EXPOSURE LIMITS A listing of acceptable exposure limits from the following sources are provid- ed on MSA’s website found at www.MSAnet.com: • American Conference of Governmental Industrial Hygienists (ACGIH) •...
  • Page 6 See MSA’s website at www.MSAnet.com for additional information. RESPIRATOR FIT TEST A qualitative or quantitative respirator fit test must be carried out for each wearer of this respirator to determine the amount of protection it will provide.
  • Page 7 APPLICATION AND OPERATING PRINCIPLE The Advantage 4000 Duo-Twin Respirator is a combination air supplied respi- rator and air purifying respirator. It is NIOSH approved for use with either par- ticulate filters and/or chemical cartridges for respiratory protection against specified contaminants.
  • Page 8 Inspect for breaks or tears and make sure all buckles are in place and working properly. b. Facepiece: Check facepiece for dirt, cracks, tears or holes. Inspect the shape of the facepiece for possible distortions that may occur from improper storage and make sure the rubber is flexible, not stiff. c.
  • Page 9 • DO NOT use an expired canister/cartridge(s)/filter(s). • DO NOT use the canister/cartridge(s)/filter(s) if the bag is opened, damaged, or missing. The canister/ cartridge(s) must be in its orig- inal packaging prior to use in a contaminated environment. Do not reuse the canister/cartridge(s)/filter(s).
  • Page 10 8. If filter is being reused, see “Replacing Cartridges/Filters” section. DURING USE When using the Advantage 4000 Duo-Twin Respirator with airline disconnect- ed, the dust cover must be placed onto the airline quick disconnect fitting (Schrader/Foster steel or SnapTite fittings only).
  • Page 11 TEST FOR TIGHTNESS THE FACEPIECE MUST BE SUBJECTED TO THE FOLLOWING TIGHTNESS TEST BEFORE EACH USE. With Air-Line disconnected, test the apparatus facepiece for tightness by holding the hands tightly over the inlet(s) of the filters or cartridges. Inhale gently so that the facepiece collapses slightly and hold breath for ten seconds.
  • Page 12 To replace filters proceed as follows: A. Remove the filter covers and discard filters. B. Place a new filter in each filter cover. Never load filters into the recepta- cles. C. Replace filter covers taking care not to damage the filters. WARNING •...
  • Page 13 Non-sudsing Confidence Plus ® Cleaning Solution (P/N 10009971) from MSA is recommended. It is a germicidal cleaner that cleans and disinfects in one operation. It retains its germicidal efficiency in hard water to inhibit the growth of bacteria. It will not deteriorate rubber, plastic, glass, or metal parts.
  • Page 14 tion for the manufacturer's recommended time. 2. Clean and Disinfect the Facepiece a. Remove the canister/cartridge(s)/filter(s) from the facepiece. b. Thoroughly wash the facepiece (and nose cup) in the cleaning solution. A soft brush or sponge can be used to clean the soiled facepiece. Be sure to include cleaning the exhalation valve and seat.
  • Page 15 • You are not color-blind and can distinguish between the beginning and ending colors of the service life indicator (when using Mersorb- P100 respirators only). Failure to follow this warning can result in serious personal injury or death. TAL 018 (L) Rev. 1 - 10089926 - DR 8-27-10...
  • Page 16 Duo-Twin Constant Flow Respirator Components (See page 17 for Facepiece) 84930 THREADED INSERT 57909 CLAMP 492827 BELT, URETHANE-COATED NYLON 9961 BELT, NYLON 473902 BELT, PVC 469713 BREATHING TUBE 57909 CLAMP 15756 NUT 83026 BELT CLIP 633954 BELT CLIP SCREW (2 REQ'D) 17554 BREATHING TUBE INSERT 628562 LOCK WASHERS (2 REQ'D)
  • Page 17 Duo-Twin Constant Flow Respirator Components (See page 17 for Facepiece) 84930 THREADED INSERT 57909 CLAMP 492827 BELT, URETHANE-COATED NYLON 9961 BELT, NYLON 473902 BELT, PVC 469713 BREATHING TUBE 57909 CLAMP 15756 NUT 83026 BELT CLIP 633954 BELT CLIP SCREW (2 REQ'D) 17554 BREATHING TUBE INSERT 628562 LOCK WASHERS (2 REQ'D)
  • Page 18 Duo-Twin Constant Flow Respirator Assembly FACEPIECE (SEE PAGE 17) 456651 BREATHING TUBE ASS'Y 457158 BREATHING TUBE ASS'Y ALTERNATE DUO-TWIN CONSTANT FLOW AIRLINE ADAPTER ASSEMBLY (SEE PAGE 12 & 13) TAL 018 (L) Rev. 1 - 10089926 - DR 8-27-10...
  • Page 19 Duo-Twin Pressure Demand Respirator TAL 018 (L) Rev. 1 - 10089926 - DR 8-27-10...
  • Page 20 10115696 10115697 TAL 018 (L) Rev. 1 - 10089926 - DR 8-27-10...
  • Page 21 NOTES TAL 018 (L) Rev. 1 - 10089926 - DR 8-27-10...
  • Page 22 NOTES TAL 018 (L) Rev. 1 - 10089926 - DR 8-27-10...

This manual is also suitable for: