Siemens SIMODRIVE base line A Technical Manual page 36

Table of Contents

Advertisement

Installation
Filter
Commutating
reactor
Shielded plate
2-24
The line filter limits the cable-borne faults emitted from the drive
converter unit to permissible EMC values for industry.
Table 2-10 Technical specification (SIEMENS filter)
Designation
Rated current
16
Power loss
20
Conductor cross
Max.4
section
PE terminal
M6, stud
Weight
3.8
Dimension
156x193x81
(WxHxD)
System voltage
400/415,±10%,3-phase AC
Degree of
IP20
protection
Humidity
3K5, condensation and icing excluded
classification
Permissible
ambient
temperature
Installation
1000, 2000 (with derating)
altitude
Order No.:
6SN1111-0AA01-1BA0
The commutating reactor is used to limit system disturbance or
instability, and store energy for step-up converter operation in
conjunction with infeed and regenerative feedback modules.
The commutating reactor is already integrated in the infeed module in
SIMODRIVE base line A. It is not required for customer to install another
commutating reactor.
In order to meet the requirements of the EC Directive on EMC, the motor
cable should be shielded. The shielded plate is used to contact the shield
on shielded motor supply cables. The plates are provided with prepared
mounting points for brake connection terminals.
Please refer to Fig.2-13 and Fig.2-14 for mounting the plate in
SIMODRIVE base line A and wiring up the cables.
Parameter
Operation: -0 ~40,max.55 (with
derating)
Storage/transport: -25~70;
SIMODRIVE base line A Start-Up
Unit
A
W
2
mm
kg
mm
V
ºC
m

Advertisement

Table of Contents
loading

Table of Contents