Siemens SIMODRIVE base line A Technical Manual page 34

Table of Contents

Advertisement

Installation
2-22
Table 2-8 Required technical specifications *
Designation
Rated power
V1 (6Nm, 11Nm, 8Nm, 16Nm): 8.00
(customer tailored)
V2 (3+3Nm, 3+6Nm, 3+8Nm, 6Nm+8Nm,
6+6Nm, 8+8Nm): 8.00 (customer tailored)
V1+V2 (8Nm +8Nm): 8.00 (standard)
Input voltage
3AC 380
Output voltage
3AC 380
Type
JBK3
Circuit voltage
<8%
UK
Terminal
IP20, Phoenix terminals are recommended
protection class
and with UL-approval
Voltage
DC 2250V, 1 minute (type test)
endurance test
Input current
<10%
without load
Vector degree
Y/Y0
Max. coil temp.
<80
boost
Remarks:
* It is valid for the tailored transformers, which is to be observed by the
customer when purchasing.
Parameter
SIMODRIVE base line A Start-Up
Unit
kVA
kVA
kVA
V
V
V
K