3.2.1 NEGATIVE SUCTION HEAD

For negative suction head filling of a machine, proceed as follows:
Close the gate on the delivery tubing
Open the priming plug
Slowly open the gate on the suction
tubing

3.2.2 POSITIVE SUCTION HEAD

For positive suction head filling of a machine, proceed as follows:
Open the gate on the suction tubing
Close the gate on the delivery tubing
Open and remove the priming plug

3.2 ELECTRICAL CONNECTIONS

WARNING
Verify that the voltage and frequency of the electropump shown on the nameplate correspond to those available on the mains.
DANGER - ELECTRIC SHOCK RISK
The installer must make sure that the electric system is grounded in accordance with the law in force.
DANGER - ELECTRIC SHOCK RISK
Make sure that the electric system has a high-sensitivity circuit breaker ∆ = 30mA (Din VDE 0100T739).
Single-phase motors have a permanently inserted condenser and a thermal protection fitted on the motor winding. Customers
will be responsible for protections of three-phase motors. Electric connections should be performed using cables H07RN-F (for
external connections) or H05RN-F or H07RN-F (for internal connections).
CHAPTER 4
STARTING THE UNIT
WARNING
Use the electropump for the applications listed on the nameplate.
WARNING
Do not operate the electropump without fluids.
WARNING
Do not operate the electropump when the interception valve on the delivery side is completely closet.
Before starting the electropump fill the electropump body as indicated at item 3.2 "Priming", check that it rotates clockwise when
looking at the electropump from the side of the motor fan. On the three phase electropumps it is possible to invert the rotation
by changing the order of two phases. It is advisable to empty the electropump and repeat the above-described operations, if the
electropump is not used for long intervals of time.
12
When the liquid flows out of the
priming plug continuously, tighten
the plug
Pour the liquid into the machine
through the priming plug hole until
the liquid starts overflowing
Close the priming plug
Fully open the gate on the delivery
and suction tubing
Start the machine
Open the gate on the delivery tubing