Step 15: Switch on the 63A DC breaker of SMILE-B3 and M4856-P, fix the maintenance cover of the
battery and recover the front panel.
Step 16: Switch on the 80A DC breaker. Then re-cover the B3 upper cover plate, use the T20 double
offset ring spanner to tightly lock the upper cover screw and insert the 8 white plugs.