Step 5: the earthing connecting position for SMILE-B3 is as shown in Figure 2.10,
please use the M4 screw.
Step 6: Connect Backup and Grid wire harness as shown in Figure 2.11.
Note: in Australia, the neutral of backup and grid circuit should be externally
connected on the neutral bar.
Note: in some places like AUS and NZL the corrugated pipes will be needed. Please
remove the original gum-elastic rings and the connectors of Backup and Grid port
waterproof contact and then replace them with the M25 pipe joints and the gum-elastic
rings in parts list.
The suggested torque for the waterproof contact is 3.75 N.m±10%.
___________________________________________________________________
Installation
Figure 2.11 Backup and Grid Wire Harness Wiring
Alpha ESS Co., Ltd.