Fitting The Guide Wire Arrangement - KSB Amarex Installation & Operating Manual

Submersible motor pump
Hide thumbs Also See for Amarex:
Table of Contents

Advertisement

26 of 82
5 Installation at Site
Nominal flange
diameter
F
y
100
2700
150
4050

5.3.1.3 Fitting the guide wire arrangement

The pump set is guided into the sump or tank along two parallel, tightly stretched
guide wires made of stainless steel. It attaches itself automatically to the duckfoot
bend which has been fitted to the floor.
NOTE
Should site conditions/piping layout, etc. require the wire to run off the vertical, do
not exceed a maximum angle of 5° to ensure reliable fitting and guiding of the
pump set.
Fitting the mounting bracket
894
90-3.37
59-18
904
920.36
572
59-24.01
571
Fig. 7: Fitting the mounting bracket
1. Fasten mounting bracket 894 to the edge of the sump opening with anchor
bolts 90-3.37 and tighten the anchor bolts to a tightening torque of 10 Nm.
2. Insert clamping pieces 571 through the holes of suspension bracket 572 and
fasten with nuts 920.37.
3. Fasten fully threaded stud 904 with the pre-assembled clamping arrangement to
the mounting bracket with nut 920.36.
Tighten nut 920.36 allowing sufficient play for subsequently tensioning the
guide wire.
Amarex
Forces
[N]
F
F
∑F
M
z
x
y
3350
3000
5250
1250
5000
4500
7850
1750
920.36
920.37
Moments
[Nm]
M
M
∑M
z
x
1450
1750
2600
2050
2500
3650

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents