Contents of the kit

Before you begin, unpack the shipment and check the parts list against the components in the shipment.
Your shipment should contain:
RTU A08 device
Support kit with the following:
2 white resistors (392Ω 1% 1/4W)
o
2 yellow resistors (1210Ω 1% 1/4W)
o
2 diodes (1N4004)
o
4 self-tapping screws (used to screw the device cover)
o

Mounting tools

The following screwdrivers are required for the installation:
One small flat screwdriver
One 0-1 flat head screwdriver

System Architecture

This is a typical system architecture in which the RTU-A08 is inserted:
The devices represented are:
TemaServer: is the controller that manages the RTU-A08. It can be both a TS AC and a TS2 device
TemaPower: is the power supply used to supply the devices. It can be one Temaline TPU-xx device
or a third party power supply.
Third Party Wiegand readers: are used to control the access to the door on entry and Exit direction