The connections shown are:
The Power supply connection: it connects the Power Supply device whit other Temaline devices
The LonWorks connection: to connect the TemaServer with the RTUs
The Input and Output are used to connect the physical door managed (lock, Door sense, REX and
others)
The Reader connections: are Wiegand lines that connect RTU-A08 with the third party readers.

Wiring Characteristics

Power supply wire

The RTU is powered at low voltage (12V
determining the correct size for power cables, refer to the table below. (Voltage cable drop max = 0,7V)
Cable Length (m) = 0,7V / (I [A] load x 2 x (R [Ohm/km] /1000))
Type of cable
AWG
mm
2
14
2
16
1.3
18
0.9
20
0.6
22
0.35
LONWORKS
Data Cables
The LONWORKS
data cable must be twisted-pair.
In a free topology configuration, the total length of the sections must not exceed 500m.
In a bus configuration, the total length of the sections must not exceed 2700m.
In a free topology configuration, activate the 51 ohm terminator by placing the appropriate jumper on the
related TemaServer device:
For TS AC close the jumper on LonWorks plug-in.
For TS2 close JP1 on the LonWorks MIP board.
For further details please refer to the related TemaServers Installation guides.
In a bus configuration, place two terminators (with resistance values of 100ohm 1% ½W) at each end of the
bus.
Check that the length of the LONWORKS
Type of cable
AWG
mm2
12
3,3
14
2
16
1,3
18
0,9
20
0,6
22
0,35
TK_S014 – Installation Manual
) by a battery-operated power supply module (RTU-Qxx). When
DC
Length (m) in relation to base load
Ohm/Km
100
[mA]
8.8
398
14
250
21
167
34
103
52
67
Table 1. Length/Capacity of Power Cables (m)
data cable corresponds to the norms indicated in Table 2.
Length [m] in relation to cable capacity
Ohm/Km
50nF/Km
5,7
2676
8,8
2153
14
1707
21
1394
34
1096
52
886
200
500
[mA]
[mA]
199
80
125
50
83
33
51
21
34
13
100nF/Km
200nF/Km 500nF/Km 1uF/Km
1892
1338
1523
1077
1207
854
986
697
775
548
626
443
1 [A]
2 [A]
5 [A]
40
20
8
25
13
5
17
8
3
10
5
2
7
3
1
846
598
681
482
540
382
441
312
346
245
280
198
9