5. Initial Display

When the study loads, the screen displays the perfusion and/or diffusion data (depending on whether
the study contains perfusion series only, diffusion series only, or diffusion and perfusion series) as
well as a ribbon with tools to help you control the workflow and add manual calculations.

5.1 Basic Image Manipulation

Right-click anywhere in the image display area to select image manipulation activities, such as
windowing, zooming, panning, and others. For a description of all image manipulation tools available
in the Vue PACS application, see the CARESTREAM Vue PACS help.
Use the mouse wheel to scroll through the series images.

5.2 Tool Ribbon

#
Description
1
Next
Step—Click to progress to the next step.
2
Select
Step—Select the next step. Steps include display of perfusion input data and display
of perfusion maps.
3
Calculate Perfusion
series only).
4
Add New
Artery—Click to manually add an artery (perfusion series, in seed mode only).
5
Add New
Vein—Click to manually add a vein (perfusion series, in seed mode only).
6
Motion
Correction—Click to correct the effect of patient movement (perfusion series only).
7
Select Damaged Brain
the hypoperfusion is assessed and segmented by the application (perfusion series only).
8
Symmetric Operation
the contralateral side when you draw an ROI.
9
Show/Hide
graphics—Use the drop-down menu to hide the ischemic regions or to hide all
graphics (perfusion series only).
10
Add
ROI—Click to manually draw an ROI.
11
Reset All
Calculations—Delete all ROIs, tissues, maps, AIF and VOF corrections.
Vue PACS MR Perfusion User Guide
AE9362 C
Vue PACS MR Perfusion User Guide - AE9362.docx
Maps—Click to initiate the calculation of perfusion maps (perfusion
Side—Specify the damaged brain side to indicate the side on which
Toggle—Click to have the application automatically draw an ROI on
Uncontrolled unless otherwise indicated
Unrestricted Internal Use
Page: 14 of 43

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vue pacs mr perfusion

Table of Contents