Table of Contents

Advertisement

Manual ACM 9 - ARE i9 release
3.2.11 LD
LD – lock memory page
LD is used to lock a particular memory page from a transponder in the field.
Input format:
LD<SP> 1<CR>
Hex:
4D
ASCII:
'L'
Output (example): 1234567812345678<CR> (content of locked memory page)
Hex:
31
ASCII:
'1'
If there is an error during locking, the answer will be XXXXXXXXXXXXXXXX<CR>

3.2.12 VSAVE

VSAVE – Save parameter permanently in ARE i9 flash memory
VSAVE is used to save parameters permanently in flash memory of ARE i9 to be available after power on.
Input format:
VSAVE <CR>
Hex:
56
ASCII:
'V'
Output (example): OK<CR>
Hex:
4F
ASCII:
'O'

3.2.13 INIT

INIT – Restore standard parameters. Command needs to be followed up by VSAVE in order to permanently store the
parameters.
Input format: INIT<CR>
Hex:
49
ASCII:
'I'
Output (example): OK<CR>
Hex:
4F
ASCII:
'O'
Manual ACM9_ARE i9 release V02.docx
44
20
31
'D'
<SP>
'1'
32
33
...
'2'
'3'
...
53
41
56
'S'
'A'
'V'
4B
0D
'K'
<CR>
4E
49
54
'N'
'I'
'T'
4B
0D
'K'
<CR>
0D
<CR>
...
38
0D
...
'8'
<CR>
45
0D
'E'
<CR>
0D
<CR>
Version: 02
Page: 21 / 43

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Id are i9

Table of Contents