MONITORING SYSTEM, GENERAL DESCRIPTIONS

1
2
3
The display on the control box gives information
about the number of operating hours, cleaning
process, alarm functions and possible faults.
Blinks when the cleaning func-
tion operates.
1 2 4
r E
4
1
Both "point" and
1
blinks when cleaning after operation is in progress.
1
The LED:s can indicate the following:
1, 2, 3______ green fixed light: All functions normal and
correct
1, 2, 3______ green fixed light alternating with blinking red:
The system operates. Incorrect function has
been rectified (alarm memory)
1, 2, 3______ red fixed light: Incorrect function which requires
investigations.
4__________ red blinking light: Incorrect function which
requires immediate investigations.
1, 2, 3 ______is only active after the inputs for the accessories
has been activated (see page 7).
Fixed light when the
system operates.
The total number of operating
hours are displayed.
r E
is displayed when trying to stop
the system from the control box when
the system is remote started.
The system has stopped and the cleaning after
operation is active. If the 0/1-button is pressed
once more the cleaning after operation is stopped
immediately.