  • Page 1 Installation Instructions Falcon IT (FIT) w w w . a m i c o . c o m w w w . a m i c o . c o m...
  • Page 2 This Instruction Manual is your guide to ensure that you get the best performance out of the equipment. Amico Accessories is not responsible for any damage as a result of (but not limited to) abuse and other problems that may be a direct or indirect result of failure to comply with the instructions provided in this manual.
  • Page 3: Table Of Contents

    Portrait Landscape Adjustment Monitor Tilt & Swivel Keyboard Tray Negative Tilt Knob System FIT Storage Rotation (Arm side-to-side) Swivel Post Spring Adjustment Section 5: Maintenance, Troubleshooting and Product Classification Troubleshooting Preventive Maintenance (FIT Station) Part Number Matrix Cleaning Warranty Information www.amico.com...
  • Page 4: Section 1: Installation Preparation

    Phillips screw driver #2 HEX keys (1/8” (0.3175cm), 3/16” 1 each (0.47625cm), M3, M4) Socket wrenches (12 mm (1.2cm), ½” 1 each (0.05cm)) Adjustable wrench NOTE: Amico does not provide any monitor hardware, nor the tools necessary for assembly. Amico Accessories Inc.
  • Page 5: Pre-Installation Information

    Considerable efforts have been made to ensure the safety of your hospital staff and your patients. The installation itself is beyond the control of Amico Accessories. Accordingly, Amico Accessories will not be responsible for failure related to the installation of the product.
  • Page 6: Typical Installation Reference Fit Station

    For mounting the FIT station, varies depending on user’s selection. Rail is packed separately and must be installed first. 10. VESA Head (Pg.28-29) For mounting the monitor 11. Mouse/Scanner Holder (Pg.16) For storing mouse and hand-held scanners. 12. CPU Mount (Pg. 7-13) (Not Shown) For Mounting CPU for FIT station. Amico Accessories Inc.
  • Page 7 Drawing is not to scale NOTE: CPU Mount should be mounted high enough so that when the FIT Station is at the highest position the monitor will not interfere with the CPU. 1.27 cm 44.45 cm 115.57 - 16.002 cm 88.9 cm www.amico.com...
  • Page 8 4. Once the arm is positioned at the desired height in the MRS, tighten all four set screws to the tightest possible position on the Mounting Adapter using a 1/8’’ HEX key. Top Stopper Mounting Adapter Bottom Stopper 1/4-20 Set MRS Rail: Length for representational use only Screws (Figure 1) (Figure 2) Amico Accessories Inc.
  • Page 9: Oshpd Anchor Pre-Approval

    SECTION 2: Installation on Rail Systems CPU Mount WARNING Ensure CPU is within weight and size rating of the CPU mount. If not, please contact Amico Accessories at (1-877-264-2697) WARNING The CPU mount can be mounted anywhere at any height on the rail. However, DO NOT mount anywhere above a patient’s head.
  • Page 10: Mounting To The Vrs/Ohmeda Rail

    V-Adapter is locked. (Figure 6) Screw Screw Slide Slide inwards Opposite side of the outwards V-adapter Unlocked Locked (Figure 1) (Figure 2) (Figure 3) Height Locking Lever V-Adapter Screws Mounted on the VRS (Figure 5) (Figure 4) (Figure 6) Amico Accessories Inc.
  • Page 11 1. Determine a suitable location on the VRS for the CPU, making sure it isn’t above a patient’s head. Also ensure your CPU mount is compatible with your CPU’s weight and size rating. If not, please contact Amico Accessories. (1-877-264-2697) 2.
  • Page 12: Mounting To The Ars Rail

    SECTION 2: Installation on Rail Systems Mounting To The ARS (Amico Rail System) FIT Station WARNING DO NOT attempt to mount/remove the FIT Station from the rail when loaded with any instrument WARNING DO NOT mount system anywhere near or above a Patient’s head.
  • Page 13 SECTION 2: Installation on Rail Systems CPU Mount WARNING Ensure CPU is within weight and size rating of the CPU mount. If not, please contact Amico Accessories at (1-877-264-2697) WARNING After the Mounting Adapters are installed, ensure that the lever on the Mounting Adapters are pressed in as far as possible.
  • Page 14: Mounting To The G Rail

    After installation, rotate the AHM arm side to side and verify no movement is present between the adapter and the rail. WARNING Removal of lock nuts will require a new set for reinstallation. Please contact Amico Accessories for spare parts, 1-877-264-2697 WARNING Ensure Headwall contains rails compatible with Mounting Adapters.
  • Page 15 SECTION 2: Installation on Rail Systems CPU Mount WARNING Ensure CPU is within weight and size rating of the CPU mount. If not, please contact Amico Accessories at (1-877-264-2697). WARNING Removal of lock nuts will require a new set for reinstallation. Please contact Amico Accessories for...
  • Page 16 2). Remove the 2 bottom screws from the VESA plate, loosen the top 2 screws, and lift the monitor off the VESA plate. M4 mounting hole for VESA-75 M4 mounting hole for VESA-100 Front of the VESA 75/100 (Figure 1) (Figure 2) Amico Accessories Inc.
  • Page 17: Mouse/Scanner Holder

    See Page 25 for instructions on locking and unlocking the AHM The Keyboard tray comes with a mouse/scanner holder. The keyboard tray contains a sliding mouse tray as well as mousepads. Amico Accessories also provides wrist rests and other accessories, however those must be purchased separately.
  • Page 18: Keyboard And Mouse

    (Figure 4). 3. Place any other accessories into their respective holders/areas and route cables according to the procedures provided in the cable management section on page 19/22. (Figure 1) (Figure 3) Dual Lock coins (Figure 2) (Figure 4) Amico Accessories Inc.
  • Page 19: Wristpad And Mousepad

    (Figure 3). (Figure 2) (Figure 3) www.amico.com...
  • Page 20: Independently Mounted Cpu

    3. Push-fit the Swivel Post Cable Cover, so that the cables pass through the Bottom 2-holes and come out from the top 2 holes (Figure 3). 4. Ensure the cables can still be moved up and down through the guide-channels. Cable guide Swivel Post Cable laid channel Cable Cover (Figure 1) (Figure 2) (Figure 3) Amico Accessories Inc.
  • Page 21 (Figure 1) (Figure 3) 3. Guide the MRS rail cable cover into the channel over the cable. Ensuring no cable is pinched between the rail and the cover. Safely trim off any excess MRS cover after installation. www.amico.com...
  • Page 22 (Figure 1) 3. Guide the ARS rail cable cover into the channel over the cable. Ensuring no cable is pinched between the rail and the cover. Safely trim off any excess MRS cover after installation. (Figure 1) Amico Accessories Inc.
  • Page 23: All In One/Cpu Mounted At Monitor

    2 holes (Figure 3). Plug the keyboard, mice, and any other accessories’ cables into the All-in-one. 4. Ensure the cables can still be moved up and down through the guide-channels. Cable guide Swivel Post Cable laid channel Cable Cover (Figure 1) (Figure 2) (Figure 3) www.amico.com...
  • Page 24 (Figure 1) 2. Guide the MRS rail cable cover into the channel over the cable. Ensuring no cable is pinched between the rail and the cover. Safely trim off any excess MRS cover after installation. (Figure 3) Amico Accessories Inc.
  • Page 25 (Figure 1) 2. Guide the ARS rail cable cover into the channel over the cable. Ensuring no cable is pinched between the rail and the cover. Safely trim off any excess MRS cover after installation. (Figure 1) www.amico.com...
  • Page 26: Section 4: Adjustments

    1. Insert the height locking lever into the mounting hole on the side of the arm (Figure 1). Turn the lever clockwise to lock vertical movement, or turn the lever counterclockwise to release the vertical lock. (Figure 2) Height Locking Lever: Rotate Counter- Clockwise to Release Rotate Clockwise to Lock (Figure 1) (Figure 2) Amico Accessories Inc.
  • Page 27: Counterbalance

    Tighten the height locking lever with the arm at the desired position, once determined. 4. If the arm is not balanced correctly, please go back to step 2 and repeat. Counterbalance Bolt (1/2”) (3.81cm) Height Locking Lever Counterbalance Bolt (1/2”) (3.81cm) Opening of the cover (Figure 1) (Figure 2) www.amico.com...
  • Page 28: Installing Extension Arm

    Remove all mounted devices before removing the FIT station from the rail. WARNING Do not reuse the removed screws to attach AHM arm base, contact Amico Accessories at (1-877-264-2697). Use part number H-HSCSP-1032-58. 1. Remove the FIT station from the rail, see FIT station mounting section on page 7-14 for instructions or contact Amico Accessories at (1-877-264-2697) 2.
  • Page 29: Portrait Landscape Adjustment

    Make the adjustments with the monitor securely mounted. NOTE: To adjust the orientation, turn the monitor (Figure 1). Do not twist/tangle wires. 1. The Portrait and Landscape adjustment is done by holding the monitor and rotating 90 degrees. Portrait Landscape (Figure 1) www.amico.com...
  • Page 30: Monitor Tilt & Swivel

    (Figure 2) ± 360° keyboard base ± 150 Screws for adjusting the Small screws swivel tension of the keyboard Large screw Nut for adjusting the swivel tension of the monitor (Figure 1) (Figure 2) Amico Accessories Inc.
  • Page 31: Negative Tilt Knob

    2. To lower the angle of the keyboard, turn the negative tilt knob counterclockwise, the keyboard tray should began lowering on its own. Continue turning the knob until desired angle is achieved. (Figure 1) Negative Tilt Knob Raise Lowers (Figure 1) www.amico.com...
  • Page 32: System

    IT Station Default Position Keyboard Tray folded and turned to the Right Turn monitor head in the AHM Arm direction of the keyboard tray Swivel Post Keyboard Tray FIT station example shown above (Figure 1) (Figure 2) Amico Accessories Inc.
  • Page 33 180 degrees. (Figure 2) Caps Bolt (Figure 1) (Figure 2) 6. Rotational tension can be adjusted by tightening/loosening the bolts located at the joints of AHM/extension arms. Remove the caps to access the bolt before adjusting (Figure 1). www.amico.com...
  • Page 34: Rotation (Arm Side-To-Side)

    For FIT Station with extension arms, both arms have a 180 degree rotation. Ensure proper clearance around the arm(s) to avoid collision. NOTE: If the arm becomes difficult to rotate, or too loose, please contact Amico Accessories: 1-877-264-2697 NOTE: Adjusting the rotational tension of the extension arms can be done by loosening or tightening the bolt at the joints of the arms and the adapter (Figure 1) using a 3/4”...
  • Page 35: Swivel Post

    2. To rotate the keyboard tray with the monitor simply rotate the keyboard tray and the monitor will rotate along with it. 3. To rotate the monitor independently of the keyboard tray, hold the keyboard tray in place and rotate the monitor. VESA plate Swivel-Post Swivel Post Cable Cover Swivel (Figure 1) (Figure 2) www.amico.com...
  • Page 36: Spring Adjustment

    4. Replace the VESA Head, re-attach the top plate with the screws and replace the cap and the swivel post cover. Top Cap Top Plate Screws Gas Spring HEX nut VESA plate Swivel-Post Swivel-Post Cover (Figure 1) (Figure 2) Amico Accessories Inc.
  • Page 37: Troubleshooting

    - Monitor drifts down/AHM drifts down - Damaged or incorrect Gas spring in AHM/ Please contact Amico Accessories Swivel post If the above solutions do not solve your symptoms or you are in need of parts/hardware, please contact Amico Accessories, 1-877-264-2697 www.amico.com...
  • Page 38: Preventive Maintenance (Fit Station)

    Please be sure to thoroughly check the areas illustrated below for FIT stations: If the above solutions do not solve your symptoms or you are in need of parts/hardware, please contact Amico Accessories, 1-877-264-2697...
  • Page 39 Area 8: Keyboard Swivel Block A) Visually inspect for any gapping between the keyboard swivel block and the AHM head. Also check for any signs of grinding on the surfaces contacting the screw and the nut. www.amico.com...
  • Page 40: Part Number Matrix

    9” (22.86cm) Extension N/A (No Extension) Datex/Ohmeda, Dovetail Direct Mount 12” (30.48cm) Extension * Direct mount options not available with extensions. 16” (40.64cm) Extension NOTE: All dimensions are not exact. ** Use MON-LCD-HANDLE for displays between 10-13lbs (25.4-33.02cm) Amico Accessories Inc.
  • Page 41: Cleaning

    Never submerge the arm and do not allow liquids to enter it. Wipe any cleaning agents off the arm immediately using a water-dampened cloth. Dry the arm thoroughly after cleaning. No Trichloroethylene No Acetone Trichloroethylene is a chlorinated Acetone is a colorless, hydrocarbon comvmonly used mobile, flammable liquid as an industrial solvent. Acetone Trichloroethylene (Figure 1) (Figure 2) www.amico.com...
  • Page 42: Warranty Information

    Amico Accessories Inc. will warrant its materials to be free from defect for an additional period of four (4) years, (five [5] years from the date of shipment). Within this period, Amico Accessories Inc. will replace any part which is proven to be defective, at no charge.
  • Page 44 Amico Accessories Inc. | www.amico.com 85 Fulton Way , Richmond Hill Ontario, L , Canada 71 East Industry Court, Deer Park NY 11729, U.S.A Toll Free Tel: 1.877.264.2697 Toll Free Fax: 1.866.440.4986 Tel: 905.763.7778 Fax: 905.763.8587 Email: info@amico.com ACC FIT MANUAL 04.05.2018...