Table 3.3 - 2251A Recalled Data Output Strings
RECALLED DATA
Unit Type
Resolution
Trigger Level A
Trigger Level B
Math Constant X
Math Constant Y
Math Constant Z
Delay Time
Special Function
Master Software Issue
VXI Processor Software Issue
Gate Time
Note: LA and LB will refer to the positive and negative peak amplitude of the signal
when Special Functions 51 and 52, respectively, are enabled.
3.6

Input Commands

3.6.1 Introduction
The 2251A responds to device-dependent commands in a "deferred" mode. This means the
2251A continues to accept commands until a terminating character or message is received;
then, the entire string will be executed. To insure that the commands have been processed
a "*OPC?" command can be given and then the response of "1" read back will indicate that
the 2251A has acted on all received commands.
3-6
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
OUTPUT STRING HEADER
UT
RS
LA
LB
MX
MY
MZ
DT
SF
MS
GS
GT