Diagnostics And Troubleshooting - Fujitsu FO2416RTJNAA Installation Instructions Manual

R-410a heat pump outdoor units, 16 seer two-stage non-communicating heat pump
Table of Contents

Advertisement

9.0 DIAGNOSTICS & TROUBLESHOOTING
9.1 Defrost Control Diagnostic Codes
LED 1
LED 2
OFF
OFF
ON
ON
OFF
ON
FLASH
FLASH
OFF
FLASH
FLASH
OFF
ON
FLASH
FLASH
O
N
ON
OFF
Alternate Flashing
9.2 Outdoor Ambient and Coil Sensor
Temperature vs. Resistance Table
Degrees F
Degrees C
-20
-10
0
10
20
25
30
40
36
Control Board Status
No Power
Coil Sensor Failure
Ambient Sensor Failure
Normal
Low Pressure Lockout (short test pins to reset)
High Pressure Lockout (short test pins to reset)
Low Pressure Control Open
H
igh Pressure Control Open
In Defrost Mode
5 Minute Time Delay
Ohms
-4
96,974
14
55,298
32
32,650
50
19,903
68
12,493
77
10,000
86
8,056
104
5,324

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fo3616rtjnaaFo4816rtjnaaFo6016rtjnaa

Table of Contents