will not operate correctly. This pathway for air must not be obstructed
2. Remove the 4 spacing brackets on the front of the appliance (Fig 19)
3. Slide the appliance into the fireplace mantle fully from the back ensuring that it is sitting in the center of the mantle.
Using suitable screws (not supplied) screw fix the appliance in place (Fig 20)
4. Be sure to position the fireplace within 1m of a power outlet (Fig 21)
Installation into a wall or recess cavity
1. Note the product dimensions in Fig 1 and build a suitable structure for the appliance to fit into within 1m of a
power outlet (Fig 22). Using suitable screws (not supplied) screw fix the appliance in place
2. Note the venting slots in the appliance. There are located at the front base and under the appliance
3. Build the wall up against the appliance using the spacing brackets as a guide.
4. There is to be an air vent at the front of the structure of at least 88cm2. It is essential to ensure that air can
circulate into the appliance – otherwise the Opti-myst flame effect will not operate correctly. This pathway
for air must not be obstructed. For examples of air vents in a wall or recess cavity see Fig 23
Connecting the Transducer Unit + Lamps
1. Release the two red tabs by turning them by 90 degrees (Fig 2)
2. Lift out the Sump Nozzle (Fig 3)
3. Insert lamps into lamp holders (Fig 4), carefully locating the pins into the holes (Fig 4a)
4. Push lamps firmly into place
5. Place the Transducer Unit into the sump and join the cable to the connector on the sump (Fig 5)
6. To ensure that the Transducer Unit is correctly placed in the sump, the tab on the Transducer Unit should be lined
up with the moulded recess in the sump (Fig 5a).
7. Ensure that the cable is not placed above the disc on the Transducer Unit (Fig 5b). To prevent the cable becoming
pinched between the nozzle and the sump, place the cable in the slot in the wall of the sump.
8. Replace the Sump Nozzle and secure it by turning the two red tabs by 90 degrees (Fig 6)
Filling the Water Tank
9. Place Water Tank in sink and remove cap (turn anti-clockwise to open) (Fig 7)
10. Fill Water Tank with filtered tap water only. This is necessary to prolong the life of the flame and smoke
producing unit. The water should be filtered through a conventional domestic water filter unit and the filter
should be replaced regularly. Distilled water must not be used.
11. Screw the cap back on – do not overtighten.
12. Place the Water Tank in the Sump, with the tank cap facing down and the flat side of the tank facing outward (Fig
8)
Assembling the fire
13. Place the Fuelbed on top of the Water Tank and Mist Nozzle (Fig 9)

Operating the Product

WARNING: FAILURE TO FOLLOW THESE OPERATING INSTRUCTIONS MAY RESULT IN INJURY AND/OR DAMAGE.
Manual Controls
The Opti-myst Manual controls are located on the base of the appliance.
(See Fig. 2 for Manual Control lay out)
Switch 'A':- Controls the electricity supply to the Fire.
Note: This switch must be in the 'ON' (I) position for the Fire to operate with or without heat when activated.
Switch 'B':- Press
once to turn on the flame effect. This will be indicated by an audible "beep". Although the main
lights operate immediately it will take a further 45 seconds before the flame effect starts.
Press
to put fire into standby mode. This will be indicated by one "beep".
Remote Control
The remote control is packed with 2 AA batteries in a bag. Lift off the battery cover on the back of the remote control
and insert the batteries taking note of the polarity.
Switching on the appliance
Press and hold the ENTER button for 3 seconds to activate the remote control. FIRE will be displayed and ON will be
blinking. Press ENTER to swtich on the appliance. To turn off the appliance press MENU so that FIRE is blinking, press
ENTER twice.
Adjust the Flame Setting
With the remote control activated press once. FIRE will be blinking on the display. Press ENTER. The current flame
setting will be displayed F1-F6. Press the UP and DOWN buttons to adjust the setting. After you have selected your
flame setting press BACK twice to exit the menu and return to the home screen.
3