HydroPoint WeatherTRAK ET Pro3 Installation Manual

HydroPoint WeatherTRAK ET Pro3 Installation Manual

Upgrade to optiflow xr
Hide thumbs Also See for WeatherTRAK ET Pro3:

Advertisement

Quick Links

WeatherTRAK ET Pro3 to OptiFlow XR
Included in Guide:
• Installation Procedure
• Controller Activation
Questions? Contact Customer Support at
support@hydropoint.com or call (800) 362-8774
Upgrade Installation Guide

Advertisement

Table of Contents
loading

Summary of Contents for HydroPoint WeatherTRAK ET Pro3

  • Page 1 WeatherTRAK ET Pro3 to OptiFlow XR Upgrade Installation Guide Included in Guide: • Installation Procedure • Controller Activation Questions? Contact Customer Support at support@hydropoint.com or call (800) 362-8774...
  • Page 2: Table Of Contents

    Contents ..............................1 ONTENTS ............................1 ETTING TARTED ET P XR ............ 1 VERVIEW OF THE TEPS FOR PGRADING FROM ..........................2 NCLUDED QUIPMENT ....................... 2 XISTING QUIPMENT THAT WILL BE ............................. 2 OOLS EEDED (CIM) ..................2 ENTRAL NTERNET ANAGEMENT ERVICE ......................
  • Page 3: Contents

    Step 11 - Activate controller with HydroPoint. Step 12 - Test the new OptiFlow XR Controller. Step 13 - Update to OptiFlow. Step 14 - Log-into WeatherTRAK.net and program WeatherTRAK OptiFlow. ©2018 HydroPoint Data Systems, Inc. All Rights Reserved 800.362.8774 • hydropoint.com...
  • Page 4: Included Equipment

    The upgrade requires an active CIM subscription service. The existing subscription will be transferred to the upgraded controller with the same end-of-service date. If you do not have an active subscription, contact HydroPoint Customer Support at 800.362.8774. Getting Started with the Upgrade Be sure to follow the step-by-step procedure when performing your upgrade.
  • Page 5: Upgrade Instructions

    Step 1 - Remove the Command Module and Disconnect Power Loosen the 4 corner pop-up screws. Lift the command module then turn it over. Carefully unplug the power cable from the mini-chassis. ©2018 HydroPoint Data Systems, Inc. All Rights Reserved 800.362.8774 • hydropoint.com...
  • Page 6: Step 2 - Disconnect Antenna And Ribbon Cable

    Plug the station keys from the ET Pro3 into the ports on the OptiFlow XR mini-chassis. The order is not important; however, it is important to start with the left-most port. ©2018 HydroPoint Data Systems, Inc. All Rights Reserved 800.362.8774 • hydropoint.com...
  • Page 7: Step 4 - Disconnect The Rain Sensor

    Disconnect the valve wires from the mini-chassis board. Step 6 - Remove the WeatherTRAK ET Pro3 Mini-Chassis Verify that the power cable has been unplugged from the mini-chassis board. Remove the grounding wire from the grounding lug.
  • Page 8: Step 7 - Install The New Weathertrak Optiflow Xr Mini-Chassis

    Position the grounding lug on one of the lower corners. Tighten the nuts on the grounding lug and the remaining 3 nuts, using the 7/16” nut driver. Connect the grounding wire to the grounding lug. ©2018 HydroPoint Data Systems, Inc. All Rights Reserved 800.362.8774 • hydropoint.com...
  • Page 9: Step 8 - Reconnect The Valve Wires And Rain Sensor

    Place the OptiFlow XR command module over the 4 pre-drilled screw holes at the top of the cabinet. Hand tighten the four corner pop-up screws. Be careful not to overtighten. OptiFlow XR Mini-Chassis OptiFlow XR Command Module ©2018 HydroPoint Data Systems, Inc. All Rights Reserved 800.362.8774 • hydropoint.com...
  • Page 10: Step 10 - Update The Date And Time

    To set the controller to automatically adjust to daylight savings time, press + or - to  select Yes. To set the controller so it does NOT automatically adjust to daylight savings time, press  + or −to select No. ©2018 HydroPoint Data Systems, Inc. All Rights Reserved 800.362.8774 • hydropoint.com...
  • Page 11: Step 11 - Activate Controller With Hydropoint

    (valve short) from a failing solenoid, “OC “ (over current) from valves drawing more than 1000 mA or “NC” (valve no-connect or open), reflecting a broken wire or wire that is not making good contact in the corresponding station terminal. ©2018 HydroPoint Data Systems, Inc. All Rights Reserved 800.362.8774 • hydropoint.com...
  • Page 12: Controller Configuration Check

    © Copyright 2018 HydroPoint Data Systems, Inc. All rights reserved. HydroPoint, WeatherTRAK, WaterCompass, and the HydroPoint logo are registered trademarks and FlowLink and OptiFlow are trademarks of HydroPoint Data Systems, Inc. Other trademarks may be held by their respective owners. Specifications, user interface, workflow, procedures, and content formats subject to change without notice ©2018 HydroPoint Data Systems, Inc.
  • Page 13: Checklists

     Disconnect the rain sensor (if applicable)  Remove the WeatherTRAK ETPro3 hardware parts that are being replaced: mini-chassis, command module, ribbon cable  Dispose of WeatherTRAK ET Pro3 parts in accordance with local E-waste laws WeatherTRAK OptiFlow XR Checklist  Record controller serial number:_____________________________________________ ...
  • Page 14 1 (800) 362-8774 support@hydropoint.com RevA20180215...

Table of Contents