Ensure that the plug is inserted into the socket securely. OVERVIEW: Unlike typical cameras, CV730-NDI leverages the easy plug-n-play benefits of the NDI-based IP 1.8 Do not overload wall sockets, extension cords or multi-way plug boards as this may workflow supported by leading video software and hardware developers around the globe.
CV730-NDI Manual Chapter 2 Package Contents Precautions Warning: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. If the UHD camera will not be used for an extended time, unplug it from the power socket.
CV730-NDI Manual 3.1.2 Back View Chapter 3 Function Introduction 3.1 I/O functions Introduction 3.1.1 Front View Item Function Descriptions RS-232 output port, at most 7 cameras can be connected in a RS-232 output serial connection RS-232 input port, at most 7 cameras can be connected in a serial...
CV730-NDI Manual Chapter 4 Instruction for installation 3.1.3 Bottom 4.1 Camera dimension: 4.1.1.1 Camera front view and side view Length x width x height: 232 x 188 x 189 mm Weight: 3.0Kg (excluding the metal plate) Item Function Descriptions...
CV730-NDI Manual 4.2 Preparation before installation Installation and connection of CV730-NDI U HD camera requires special skills. To install 4.3.2.2 Metal Plate size diagram by yourself, please follow necessary steps, ensure steady and tight installation of the device, and pay attention to your safety to avoid any accident.
Page 8
CV730-NDI Manual Metal plate A - machine side 4.3.2.3 Precautions for installation 1. Before installation, please confirm the orientation of the machine relative to the object to be captured 2. It is recommended that the machine should be set at a distance more than 2 meters away from the object to be captured.
Page 9
CV730-NDI Manual black screw 2. Fix the metal plate A on the machine base with 4 M3 silver screws 4.3.2.5 How to remove 1. Remove the connecting wires from the camera 2. Uninstall the camera together with the ceiling, loosen the three screws that fix the metal plates A and B and push to the left to remove the machine 3.
CV730-NDI Manual 4.4 Connecting devices 4.4.2 Connecting RS-422 With RS-422, at most 7 Marshall cameras can be connected. 4.4.1 Connecting RS-232 ut, at most 7 Marshall cameras can be connected. <Caution> When RS-422 connection is being used, do not use RS-232 With RS-232 in/out, at most 7 Marshall cameras can be connected.
CV730-NDI Manual Chapter 5 Remote Control and Setting Menu RS-422 connection instructions 1. Hold the two sides of RS-422 connector and pull out in the direction shown by the 5.1 Functions of remote control arrow in the figure below <Remark>...
CV730-NDI Manual 5.1 Setting Menu <Remark>Press [Menu] on the remote control to enter the setting menu; the bold underlined values in the following table are defaults. 1st Level 2nd Level 3rd Level Function Descriptions Major Items Minor Items Adjustment Values 1.
Page 13
CV730-NDI Manual 1/3000 1/3000 1. 9 dB 1/2500 1/2500 2. 12 dB 1/2000 1/1750 3. 15 dB 1/1500 1/1250 4. 18 dB 1/1000 1/1000 5. 21 dB 1/725 1/600 6. 24 dB 1/500 1/425 Max. limit value of Gain Limit 7.
Page 14
CV730-NDI Manual Adjustable when the Manual Blue 0 ~ C ~ 128 white balance mode is Pan Right Limit 0 ~ 170 Limit the right angle set to Manual Pan Left Limit -170 ~ 0 Limit the left angle 1. Off...
Page 15
CV730-NDI Manual This function can only be Audio In Line In/Mic In Set Audio In enabled in the Manual Focus (MF) mode Audio Audio Enable On / Off Turn on/off audio output When PTZ Assist is Audio Volume 0 ~ A ~ 10...
CV730-NDI Manual Chapter 6 Network Function Settings Description Choose the transmission Baud Rate 9600/38400 speed of the control Connecting Camera to Network signal The Protocol set to 6.1.1 Connecting to Internet VISCA allows the Two common connection methods are shown below...
Page 17
CV730-NDI Manual 6.1.2 Using the Browser to View the Images Open the browser, and enter the URL of camera in the IP address bar e.g.: http://192.168.100.100 (default IP address) Enter administrator’s account and password *For the first login, please refer to the default 6.2.3 User Management Modify...
CV730-NDI Manual Web Page Function Description 6.2.2 Viewing In Real Time 6.2.1 Login Screen CV730-NDI Item Function Descriptions Username Enter user account (default: admin) Enter user password (default: 9999) Password *For the first login, please refer to 6.2.3 User Management Modify...
Page 19
CV730-NDI Manual 6.2.3 Account Management 6.2.4 Setting - System Setting CV730-NDI CV730-NDI Item Function Descriptions Add user account Enter a user name and password to add a new user Set the new account management permissions User Type Admin Operator Viewer...
Page 20
Mode: Select exposure mode (Automatic/Shutter Priority/Aperture letters or numbers. Do not use “/” and “space” or special symbols Priority/Manual) Streaming 1/Streaming CV730-NDI supports 3 streaming outputs. Please refer to 6.2.5.1 Exposure Comp. Level: Select exposure compensation level 2/Streaming 3 Streaming Parameter Setting...
Page 21
CV730-NDI Manual 6.2.7 Setting – Picture CV730-NDI Mode: Select the color temperature mode White Balance Auto Indoor Outdoor One Push WB Manual Sodium Lamp Open Push WB: One push color temperature is adjustable when ...
Page 22
CV730-NDI Manual 6.2.8 Setting – Audio 6.2.9 Setting – Network CV730-NDI Marshall Item Function Descriptions Item Function Descriptions Network setting of camera. Change of setting is available when DHCP Open audio Turn on/off sound Network function is closed. Soundtrack effect...
Page 23
CV730-NDI Manual 6.2.11 Setting - Maintenance - Upgrading Firmware 6.2.10 Setting – Time CV730-NDI CV730-NDI Item Function Descriptions Item Function Descriptions The camera firmware may be upgraded via web page. For the upgrade Camera Time Display the date and time of the camera...
CV730-NDI Manual Chapter 7 DIP Switch Setting 6.2.13 Setting - Maintenance - System Service 7.1 DIP SWITCH CV730-NDI 7.1.1 OUTPUT Switch (Switch to different output resolutions) To switch via the OSD/ RS-232 Command is also available based on the last...
FCC Declaration of Conformity 47 CFR § 2.1077 Compliance Information This chapter describes problems you may encounter while using CV730-NDI. If you have U.S. Contact Information questions, please refer to related chapters and follow all the suggested solutions. If the problem Company:Marshall Electronics, Inc.
Warranty Marshall Electronics warranties to the first consumer that this device will, under normal use, be free from defects in workmanship and materials, when received in its original container, for a period of two years from the purchase date. This warranty is extended to the first consumer only, and proof of purchase is necessary to honor the warranty.