Atlantis Pre-Dive Inspection Checklist
Diver Name_____________________________ Date_____________
Atlantis Number_________
WArNiNg: Before each use, the Atlantis must be given a thorough visual inspection
and functional test. NEVER dive with an Atlantis BC that shows signs of damage to its
bladder or valves until it has received a complete inspection and service.
initials
______ 1. Visually Inspect the Atlantis, all harness assemblies and buckles.
______ 2. Check the oral inflator button shaft for corrosion. This can be done by looking
______ 3. Manually exercise the Rapid Exhaust Valve (REV) by pulling on the spiral
______ 4. Install 2 fully charged 3000 PSI (206 BAR) air cylinders to the Atlantis.
______ 5. Orally inflate the Atlantis until the bladder is completely full. Slightly open the
______ 6. While the vest is still inflated, check the function of both the REV and the
______ 7. Check the dual valve connector, caps and cylinder valve connectors, making
______ 8. Fully inflate the Atlantis once again and let it sit for 10 minutes to check for
______ 9. Verify that all harness straps are connected properly in the correct mission
______ 10. Diving Supervisor will check previous steps and record deficiencies below.
WArNiNg: If any leakage can be heard or if the bladder begins to deflate within 10 minutes,
Do Not attempt to use the Atlantis until it has been repaired by a trained technician.
Remarks
Divers Signature
through the inspection holes in the side of the oral inflator lower assembly and
inside the mouthpiece.
hose, .25 in (7 mm) is all the pull required to open the REV. Excessive force
will damage the airway.
valve on the air cylinder to over-pressurize the Atlantis until the OPRV opens
to relieve excess pressure. Close the cylinder valve. Verify the OPRV reseats
and keeps the bladder fully inflated. Recharge the cylinder as required.
oral inflation valve (See Deflation Methods). Ensure rapid and unobstructed
exhaust from each valve.
sure they are sealed and no air is escaping.
leaks and firmness.
configuration. Verify all buckles operate correctly.
Diving Supervisor Signature