Advertisement

Model FH94 Gas
Owner's Manual
WARNING:
Improper installation, adjustment, alteration, maintenance can cause property damage, injury,
or death. Read the installation, operating and maintenance instructions thoroughly before
installing or servicing this equipment.
CAUTION:
In a prominent location, post instructions to be followed in the event the user smells gas. This
information shall be obtained by consulting your local gas supplier.
Broiler must be kept free of combustible materials, and the flow of ventilation air must not be
obstructed. Operating personnel must not perform any maintenance or repair functions.
Contact your Nieco Authorized Service Agent for service or repair.
Fill in the information bellow and have it handy when calling your authorized service agency for assistance.
The serial number is on the broiler rating plate on the back of the unit.
Purchased from: __________________________________________________________
Date of Purchase: _________________________________________________________
Model No.: _______________________________________________________________
Serial No.: _______________________________________________________________
IMPORTANT: RETAIN THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FH94 Gas and is the answer not in the manual?

Questions and answers

Summary of Contents for Nieco FH94 Gas

  • Page 1 Broiler must be kept free of combustible materials, and the flow of ventilation air must not be obstructed. Operating personnel must not perform any maintenance or repair functions. Contact your Nieco Authorized Service Agent for service or repair. Fill in the information bellow and have it handy when calling your authorized service agency for assistance.
  • Page 2 3. Operating personnel must not perform any maintenance or repair functions. Contact your Nieco Authorized Service Agent. 3. Do not use this appliance in an area where a water jet could be used.
  • Page 3: Table Of Contents

    Clean Monthly ..........34-35 Model FH94 Gas...
  • Page 4: General Information

    This manual provides the safety, installation and operating procedures for the Nieco Automatic Broiler Model FH94. We recommend that all information contained in this manual be read prior to installing and operating the broiler.
  • Page 5: C Service/Technical Assistance

    General Information C. Service/Technical Assistance If you experience any problems with the installation or operation of your broiler, contact your local Nieco Authorized Service Agent. You may contact the factory direct at +1-707-284-7100 if you have trouble locating your local Authorized Nieco Service.
  • Page 6 • Use only genuine Nieco replacement parts for your broiler. Failure to do so will void the warranty and may significantly alter the performance of your broiler. The use of non-Nieco parts is capable of affecting these criteria, and may affect broiler performance, parts longevity and food safety.
  • Page 7: Machine Installation

    REQUIRED CLEARANCES Installation near combustible walls Installation near non-combustible walls and construction and construction Back of broiler 12" (305 mm) 0” (0 mm) Sides of broiler 12" (305 mm) 0” (0 mm) Model FH94 Gas...
  • Page 8: F Gas Connection

    For easy movement of the appliance, the connector should be installed with a “lazy” loop for minimum tension. Note: Gas appliances should be disconnected prior to maximum movement. Model FH94 Gas...
  • Page 9: H Restraining Device

    Note: Disconnect power before servicing. J. Pre-Operation Check Be sure that all parts are installed in the proper location:  Ventilation is turned on  Broiler is plugged in  Gas line is connected Model FH94 Gas...
  • Page 10: Operation

    Touch Screen Control Panel: • Controls all operation of the broiler • Turns on/off cook chamber The Touch Screen Control Panel takes approximately 30-45 seconds to power on after main power switch has been turned on. Model FH94 Gas...
  • Page 11: Touch Screen Controls

    Power Manager Settings Tap to access on/off for Access controls for cook chamber Temperature, Editing Recipes, and Calibration Cleaning Tap to access cleaning Default Password: 123 sequence visual guide. Factory Settings Not accessed for general operation purposes. Model FH94 Gas...
  • Page 12: Lighting Procedures

    2. Use Touch Screen Control to turn on cooking chamber. 3. Verify ignition is complete, and all burners are lit. 4. Allow broiler to heat for 45 minutes before cooking. Model FH94 Gas...
  • Page 13: Troubleshooting: Ignition Failure

    Chamber(s). Turn Chamber OFF from the Touch Screen Control Panel, wait 15 seconds, then turn the Chamber back to ON. If this still doesn’t light the broiler, see the MANUAL IGNITION instructions. Model FH94 Gas...
  • Page 14: Manual Ignition Guide

    3. Use Touch Screen Control to turn on cooking chamber. 4. Hold a lighter/match to the Upper Burner on the discharge end until the burner lights. 5. Once the first burner is lit, verify that all burners have ignited. 6. Replace the Rear Awning. Model FH94 Gas...
  • Page 15: Shutdown Procedures

    5. Wait for the broiler to cool MAIN POWER SWITCH. to begin Daily Cleaning. EMERGENCY SHUTDOWN Your Nieco Automatic Broiler 1. Turn off the 2. Close the MAIN POWER MAIN GAS VALVE is designed to automatically SWITCH. stop gas flow to the broiler...
  • Page 16: Basic Operation: On/Off

    • Controls all Wait 30–45 Seconds for operation of the Touch Screen Control to broiler Power On • Turns on/off cook chamber Touch Power to Touch Toggle Switch To Turn Cooking Chamber On Turn On or Off Model FH94 Gas...
  • Page 17: Selecting A Recipe

    Click next recipe (semi-circle) to toggle and select the recipe for each Belt Lane. Lane 1 is the Left Belt Lane 2 is the Right Belt Touch to Toggle Recipe Selection For Left Belt Touch to Toggle Recipe Selection For Right Belt Model FH94 Gas...
  • Page 18: Manager Settings Control Screen

    2. Allow broiler to heat for 45 minutes. 3. Perform Cookout. 4. Adjust Recipe cook time as necessary to achieve BKC Cookout Specifications. Note: Calibration button is not currently used for the Calibration process. Recipe Settings Touch to enter the Recipe Screen Model FH94 Gas...
  • Page 19: How To Adjust Recipe Cook Time

    Select to confirm Tip: As a general guide, new recipe setting, then 5 additional seconds ← touch to return to the will increase product Manager Settings Screen. temperature by 2°-5°. Edit Name Touch Recipe Name to edit Model FH94 Gas...
  • Page 20: How To Add A New Recipe

    Save temperature by 2°-5°. Select to confirm new recipe setting, then Deleting a Recipe ← touch to return to the Manager Settings Screen. Touch and hold Recipe Name, then touch Yes to Delete selected Recipe. Model FH94 Gas...
  • Page 21: Cleaning Process Visual Guide

    You can access a visual guide to the cleaning process from the touch screen control home screen. The images reflect the same process contained in this manual and in the FH94 cleaning chart poster. Every 4 Hours Daily Cleaning Touch to access cleaning sequence visual guide. Weekly Monthly Model FH94 Gas...
  • Page 22: Assembly/Disassembly And Cleaning

    When to clean the part Every 4 Hours The tools needed to clean the part Daily Picture of the part to be removed and cleaned How to remove and clean the parts Weekly Step in Cleaning Chart Frequency Color Code Monthly Model FH94 Gas...
  • Page 23 This warning symbol shows a step in the procedure that must be followed exactly or broiler performance could be affected. This “puzzle” symbol shows an important step in the reassembly procedure to follow carefully. Model FH94 Gas...
  • Page 24: Clean Every 4 Hours

    Clean: Every 4 hours Feeder Cover Feed End Tools 3-Compartment Sink Scrub Pad Instructions 1. Slide the feeder cover towards you until it comes off. 2. Wash with scrub pad, rinse, and sanitize in the 3-compartment sink. Model FH94 Gas...
  • Page 25 Clean: Every 4 hours Feeder Housing Enclosure Feed End Tools 3-Compartment Sink Scrub Pad Instructions 1. Lift and remove. 2. Wash with scrub pad, rinse, and sanitize in the 3-compartment sink. REASSEMBLY: Hang feeder housings on brackets. Model FH94 Gas...
  • Page 26: Clean Daily

    Scrub Pad Heat-Resistant 3-Compartment Sink Gloves Degreaser Instructions 1. Slide holding pan bracket up and out. 2. Take to sink area and spray with degreaser. 3. Wash with scrub pad, rinse, and sanitize in the 3-compartment sink. Model FH94 Gas...
  • Page 27 Hotel Pan Discharge End Tools 3-Compartment Sink Scrub Pad Degreaser Instructions 1. Slide out and empty. 2. Take to sink area and spray with degreaser. 3. Wash with scrub pad, rinse, and sanitize in the 3-compartment sink. Model FH94 Gas...
  • Page 28 Clean: DAILY Cover and Awning Discharge End Tools 3-Compartment Sink Scrub Pad Degreaser Instructions 1. Remove Cover 2. Swing and lift up Awning to remove. 3. Wash with scrub pad, rinse, and sanitize in the 3-compartment sink. Model FH94 Gas...
  • Page 29 Stripper Grease Tray Discharge end Tools 3-Compartment Sink Scrub Pad Degreaser Instructions 1. Lift tray up and out. 2. Take to sink area and spray with degreaser. 3. Wash with scrub pad, rinse, and sanitize in the 3-compartment sink. Model FH94 Gas...
  • Page 30 Remove Daily Carbon Build-up: Shaft & Belts Discharge End Tools Airbox Wrench/ Shaft Cleaning Tool Belt Scraper Tool Instructions CAUTION: EXTREMELY HOT. Allow to cool before handling. 1. Remove Carbon Build-up from shafts and belts with supplied cleaning tools and brushes, or equivalent. Model FH94 Gas...
  • Page 31 Allow to cool before handling. 1. Lift Incendalyst up and off. ™ 2. Rinse clean with water only. The Incendalyst ™ may be soaked, then rinsed if needed. 3. Shake out excess water thoroughly. CLEAN WITH WATER ONLY! Model FH94 Gas...
  • Page 32 3. Wash with scrub pad, rinse, and sanitize in the 3-compartment sink. Clean: WEEKLY Remove Lower Burner Feed End Tools Heat-Resistant Gloves Instructions CAUTION: EXTREMELY HOT. Allow to cool before handling. 1. Open latch, then lift Lower burners up, then out. Model FH94 Gas...
  • Page 33: Clean Weekly

    Clean: MONTHLY Disconnect Upper Airbox Tools Heat-Resistant Airbox Wrench/ Gloves Belt Scraper Tool Instructions CAUTION: EXTREMELY HOT. Allow to cool before handling. 1. Remove air hose with supplied wrench or equivalent. REASSEMBLY: Reinstall air hose, hand-tighten only Model FH94 Gas...
  • Page 34 1. Lift out airbox by handle. Clean: MONTHLY Clean Upper Airbox Tools Cleaning Brush Instructions CAUTION: EXTREMELY HOT. Allow to cool before handling. 1. Clean with supplied wire brush or equivalent, making sure holes are clear. REASSEMBLY: Reinstall air hose, hand-tighten only Model FH94 Gas...
  • Page 35 1. Lift Upper Burner up and out. Clean: MONTHLY Clean Upper Burner Tools Cleaning Brush Instructions CAUTION: EXTREMELY HOT. Allow to cool before handling. 1. Clean with supplied wire brush or equivalent, making sure holes are clear. Model FH94 Gas...
  • Page 36 FH94G III. OPERATION Revision History: Date Notes Revision 7950 Cameron Drive Windsor, CA 95492 Phone: 707.284.7100 Fax: 707.284.7430 service@nieco.com Printed in the USA © 2020 Nieco Corporation All Rights Reserved P/N 99107...

This manual is also suitable for:

Fh94g

Table of Contents

Save PDF