Stihl HSA 94 T Instruction Manual page 39

Hide thumbs Also See for HSA 94 T:
Table of Contents

Advertisement

Available languages

Available languages

23 Troubleshooting Guide
Always remove the connecting cord before carrying out any inspection, cleaning or maintenance.
Condition
LEDs on
Battery
Hedge trimmer cuts
1 LED glows
out during operation.
red.
3 LEDs glow
red.
Runtime is too short.
0458-722-8221-A
Cause
Remedy
Battery too hot / too
► Remove the connecting cord, @ 14.2.
cold.
► Allow the hedge trimmer and battery to cool down gradually
Hedge trimmer too
at ambient temperatures of about 50 °F to 68 °F (10 °C to
hot.
20 °C).
Battery not fully
► Charge the battery as described in its instruction manual.
charged.
Useful life of battery
► Have the battery checked by an authorized STIHL servicing
has been reached or
dealer.
exceeded.
English
37

Advertisement

Table of Contents
loading

Table of Contents