Stihl GS 461 Instruction Manual page 20

Hide thumbs Also See for GS 461:
Table of Contents

Advertisement

Available languages

Available languages

English
Decompression valve
Press the button, the
N
decompression valve will be
opened
The decompression valve is closed
automatically when the engine fires for
the first time. For this reason, press the
button again before each additional
starting attempt.
DANGER
There must not be anyone within the
swivel range of the concrete cutter.
18
STOP
2
Simultaneously press the throttle
N
trigger lockout (2) and throttle
trigger (3) – set the master control
lever
Position cold start l
If engine is cold (even if the engine
has stalled during opening of
throttle after starting)
Position warm start n
If engine is warm (once the engine
has been running for approx. one
minute)
Hold and start the concrete cutter
N
When the engine has turned over for the
first time
1
Move the Master Control lever (1) to
N
the position warm start n
Press the button on the
N
decompression valve
Hold and continue cranking the
N
concrete cutter
Once the engine is running
Blip the throttle trigger (2); the
N
Master Control lever (1) jumps to
run F and the engine begins to idle
The concrete cutter is now ready for use.
At very low temperatures
Let the engine warm up briefly with
N
the throttle slightly open
STOP
1
STOP
1
2