Ergoswiss SLA VD Series Operating Instructions Manual

Ergoswiss SLA VD Series Operating Instructions Manual

Spindle lifting system

Advertisement

Quick Links

Operating instruction - Spindle lifting system SLA/SLG VD
It is essential to read this operating instruction thoroughly before commissioning the system.
This operating instruction has to be stored in the immediate vicinity of the system.
Linear unit type SLA or SLG
Control box VD SCT
Errors and technical changes reserved.
Ergoswiss AG does not assume any liability for operating
errors or using the products outside of the intended
purpose use.
At the time of delivery Ergoswiss AG will replace or re-
pair defect products within accordance with the war-
ranty provisions. In addition, Ergoswiss assumes no
other liability.
For your questions and special custom demand
Ergoswiss AG will be at your disposal.
Document no.: B-00081
Edition 2019 02
1
Manual control switch Up/Down or Memory
Operating instruction EN
Copyright by Ergoswiss AG
Operating Instruction
Spindle lifting system SLA/SLG VD
2
3
Ergoswiss AG
Nöllenstrasse 15
CH-9443 Widnau
Tel.: +41 (0) 71 727 06 70
Fax: +41 (0) 71 727 06 79
info@ergoswiss.com
www.ergoswiss.com
1/20

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLA VD Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ergoswiss SLA VD Series

  • Page 1 CH-9443 Widnau purpose use. Tel.: +41 (0) 71 727 06 70 At the time of delivery Ergoswiss AG will replace or re- Fax: +41 (0) 71 727 06 79 pair defect products within accordance with the war- ranty provisions. In addition, Ergoswiss assumes no info@ergoswiss.com...
  • Page 2 Stroke length in cm 30, 40 cm Power cable EU, CH, IT, UK, US 11= manual control switch up/down ; 12= Memory 11, 12 -> (VD) Operating instruction EN Document no.: B-00081 2/20 Edition 2019 02 Copyright by Ergoswiss AG...
  • Page 3: Table Of Contents

    Electrical and Electronic Equipment Act ....................17 Error messages on the display (Only with manual control switch type Memory!) ........18 Trouble-shooting ..........................19 Declaration of Incorporation ........................20 Operating instruction EN Document no.: B-00081 3/20 Edition 2019 02 Copyright by Ergoswiss AG...
  • Page 4: System Description

    1 System description 1.1 General The basic functionality of a spindle lifting system SLA/SLG by Ergoswiss AG is the lifting and lowering of work surfaces, machine parts, profile systems, etc. An operative spindle lifting System SLA/SLG consists of a minimum of following components: •...
  • Page 5: Performance Characteristics

    1.4.5 Manual control switch VD Up / Down and memory Kable length 2'000 mm Ambient temperature 0 – 40 °C Protection class (DIN EN 60529) IP 30 Operating instruction EN Document no.: B-00081 5/20 Edition 2019 02 Copyright by Ergoswiss AG...
  • Page 6: Safety Requirements

    Non-compliance with this information can result in damage to property or light to medium personal injuries. NOTE Indicates general notes, useful operator advice and operating recommendations which do not affect safety and health of the user. Operating instruction EN Document no.: B-00081 6/20 Edition 2019 02 Copyright by Ergoswiss AG...
  • Page 7: Basic Safety Instructions

    → Only use a dry or a damp cloth to clean the control box! Before cleaning, the power cable has to be separated from the mains! Operating instruction EN Document no.: B-00081 7/20 Edition 2019 02 Copyright by Ergoswiss AG...
  • Page 8: Preperation For First Initial Operation

    The motor cable, connecting the control box to the motor, has a length of 2’000 mm. If needed, up to 2 motor extension cables can be connected. They have a length of 1’500 mm. → 124.0237: VD Extension cable 1’500 mm Motor Operating instruction EN Document no.: B-00081 8/20 Edition 2019 02 Copyright by Ergoswiss AG...
  • Page 9 → Are the plugs of the motor cable connected to the correct sockets (M1-M2)? → Is the entire lifting system assembled according to the assembly instructions? Operating instruction EN Document no.: B-00081 9/20 Edition 2019 02 Copyright by Ergoswiss AG...
  • Page 10: Mounting Of The Manual Control Switch

    Fasten the mounting plate using the mounting screws. Be careful not to drill through the table top! Slide the manual control switch onto the mounting plate. Operating instruction EN Document no.: B-00081 10/20 Edition 2019 02 Copyright by Ergoswiss AG...
  • Page 11: Manual Control Switch Vd Memory T6

    The control panel must overhang below the work surface! Fasten the manual control switch using the mounting screws. Be careful not to drill through the table top! Operating instruction EN Document no.: B-00081 11/20 Edition 2019 02 Copyright by Ergoswiss AG...
  • Page 12: Initial Operation

    (The lower position is 3 to 4 mm higher than the block position. The upper position depends of the lifting element type, resp. of the control box software.) Operating instruction EN Document no.: B-00081 12/20 Edition 2019 02 Copyright by Ergoswiss AG...
  • Page 13: Operation

    (Only with manual control switch type Memory!) This function is designed to approach a stored position. → Keep one of the buttons pressed. The system approaches and stops at the stored position. Operating instruction EN Document no.: B-00081 13/20 Edition 2019 02 Copyright by Ergoswiss AG...
  • Page 14: Container-Stop And Shelf-Stop-Positions (Only With Manual Control Switch Type Memory!)

    Drive the system to the programmed lowest position. Keep the buttons pressed simultaneously. System will drive to the lower block position and adjust itself like during the initial operation. Operating instruction EN Document no.: B-00081 14/20 Edition 2019 02 Copyright by Ergoswiss AG...
  • Page 15: Synchronous Operation Of 2 Control Boxes

    If the SYNC cables are connected afterwards, they will not be recognised by the control box and only one drive will move, which can lead to jamming of the entire system. Operating instruction EN Document no.: B-00081 15/20 Edition 2019 02 Copyright by Ergoswiss AG...
  • Page 16: Safety Strip - Squeezing Protection

    Spindle lifting system SLA/SLG VD 7 Safety strip - Squeezing protection With lifting systems of Ergoswiss AG it is important to make sure that no objects or people are trapped dur- ing the lifting movement. ->Danger of squeezing Attach the safety strip to an assumed squeeze zone. If the safety strip gets squeezed while the system moves, the motor will stop instantly and turn back for 14 motor turns.
  • Page 17: Maintenance And Disposal

    2012/19/EU), since the lifting system – in accordance with the intended purpose use – is not intended for end-users (business-to-customer) but for industrial applications (business-to-Business) is designed. Operating instruction EN Document no.: B-00081 17/20 Edition 2019 02 Copyright by Ergoswiss AG...
  • Page 18: Error Messages On The Display (Only With Manual Control Switch Type Memory!)

    Short-circuit -> motor Replace the defect motor with a new one and per- form a reset.. F 222 F DE EEPROM error F 233 F E9 MOSFET defect Operating instruction EN Document no.: B-00081 18/20 Edition 2019 02 Copyright by Ergoswiss AG...
  • Page 19: Trouble-Shooting

    Drive only move to one direction Manual control switch defective Replace the manual control switch Drive only moves downwards System overload Remove weight from the system Operating instruction EN Document no.: B-00081 19/20 Edition 2019 02 Copyright by Ergoswiss AG...
  • Page 20: Declaration Of Incorporation

    Operating Instruction Spindle lifting system SLA/SLG VD 9 Declaration of Incorporation Operating instruction EN Document no.: B-00081 20/20 Edition 2019 02 Copyright by Ergoswiss AG...