Temperature Sensor; Fan - SHERCO ST Series Workshop Manual

Hide thumbs Also See for ST Series:
Table of Contents

Advertisement

ELECTRICAL PART
❱❘ Temperature sensor
Drain the coolant.
Remove the radiator temperature sensor.
Immerse the sensor
[2],
with coolant
terminals asleep with the liquid.
Immerse a thermometer [3] in the liquid so
as to control its temperature.
Heat the liquid slowly and check the
resistance of the sensor using a connected
multimeter as in the diagram according to
the temperature of the liquid, refer to the
table below.
❱❘ Ventilator
Disconnect the fan from the harness.
Connect a 12V battery directly to the fan as
shown in the diagram.
Check that the fan rotates correctly without
any hard point or abnormal noise.
43
[1]
in a container filled
making sure to leave the
TEMPS (°C)
25
30
40
50
60
70
80
90
100
RESISTANCE (Ω)
ST SERIES
3000
2415
1620
1081
748
528
379
278
206