Ecoflo NATURE LOO EXCELET CS Installation & Maintenance Manual

Advertisement

Quick Links

EXCELET CS & EXCELET
Thank you for purchasing the Excelet model. Please read this manual carefully before installation.
"Nature Loo" is a brand of Ecoflo
Visit our website at ecoflo.com.au
IMNL-003.181008
Installation & Maintenance Manual
Wastewater Management Pty Ltd.
© Ecoflo Wastewater Management Pty Ltd
®
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Ecoflo NATURE LOO EXCELET CS

  • Page 1 Installation & Maintenance Manual ▪ Thank you for purchasing the Excelet model. Please read this manual carefully before installation. ▪ Wastewater Management Pty Ltd. “Nature Loo” is a brand of Ecoflo ▪ Visit our website at ecoflo.com.au Page 1 IMNL-003.181008...
  • Page 2 Copyright © 2018 Ecoflo Wastewater Management Pty Ltd Please call your local distributor or Ecoflo Wastewater Management for support if required. Ecoflo Wastewater Management Pty Ltd www.ecoflo.com.au www.natureloo.com.au Phone: 1300 138 182 Phone: 07 3889 6144 Email: info@ecoflo.com.au ABN 33 606 583 895...
  • Page 3: Table Of Contents

    TOILET USE & MAINTENANCE ....................22 EXCHANGING THE COMPOST CHAMBER ................23 THE COMPOSTING PROCESS ....................26 TROUBLE SHOOTING ........................28 HOW TO DEAL WITH VINEGAR FLIES ..................31 PRODUCT & COMPONENT WARRANTY ..................32 MAINTENANCE SCHEDULE ..................34 Page 3 IMNL-003.181008 © Ecoflo Wastewater Management Pty Ltd...
  • Page 4 0.30 cubic metre 20 mm Aggregate  50mm PVC pipe to connect the hose to the agricultural pipe  Purchase a Drain Kit from Ecoflo. The following tools will be required to complete the installation: Page 4 IMNL-003.181008 © Ecoflo Wastewater Management Pty Ltd...
  • Page 5: Toilet Installation

    An elevated starting point for liquid to flow by gravity from the toilet down into a liquid absorption trench which is to be dug outside the toilet room. The toilet must also be located close to a power source. E.g. Page 5 IMNL-003.181008 © Ecoflo Wastewater Management Pty Ltd...
  • Page 6: Step 2: Installing The Vent Pipe & Liquid Drain

    Using the circles drawn on the wall as a guide, cut a hole of sufficient size to allow the 50mm DWV PVC pipe to push through the wall and a second hole (approximately 25mm) for the liq- uid drain hose. Page 6 IMNL-003.181008 © Ecoflo Wastewater Management Pty Ltd...
  • Page 7 Most people choose to locate the pedestal as close to the wall as possible (remember to leave enough room for the pedestal lid to be removed when changing chambers). Page 7 IMNL-003.181008 © Ecoflo Wastewater Management Pty Ltd...
  • Page 8 100mm DWV PVC pipe as per Option 1 or Option 2 (pictured above). If possible, Op- tion 1 is far better for ventilation as the two 45 degree elbows in Option 2 can slow the air Page 8 IMNL-003.181008 © Ecoflo Wastewater Management Pty Ltd...
  • Page 9 Once the toilet is permanently connected to the ‘T’ piece you may attach the fibreglass toilet bottom to the floor with the self tapping screws and nylon washers (supplied) and / or an seal- ant (not supplied). Page 9 IMNL-003.181008 © Ecoflo Wastewater Management Pty Ltd...
  • Page 10 The hose exiting through the hole in the shell should lead through the hole previously cut into the bathroom wall and out towards the absorp- tion trench. Construct the excess liquid drain absorption trench as per the following diagrams. Page 10 IMNL-003.181008 © Ecoflo Wastewater Management Pty Ltd...
  • Page 11 We recommend a spare fan is kept on hand at all times, particularly after a year of use. Go to Ecoflo Online Store or call 1300 138 182 for replacement or spare fans. Solar Power – refer to Solar Panel Installation Manual Page 11 IMNL-003.181008 © Ecoflo Wastewater Management Pty Ltd...
  • Page 12  In the event of failure during the warranty period, the faulty fan must be returned to Ecoflo who will ship a replacement by regular mail service on the next business day providing the above conditions have been met.
  • Page 13: Step 5: Assembling The Compost Chamber

    Tighten untill most of the thread is in the hole (leave 5-10mm showing). Place the false floor in- side the chamber with the flat side down. Page 13 IMNL-003.181008 © Ecoflo Wastewater Management Pty Ltd...
  • Page 14 Use a multitool wrench if you cannot tighten the socket sufficiently by hand. Once finished the compost chamber should look like the picture above. Repeat for all remaining chambers. Page 14 IMNL-003.181008 © Ecoflo Wastewater Management Pty Ltd...
  • Page 15 After 5 days add half a pack of Nature Quick microbes to the cham- ber. Follow the instructions on the pack and use the other half in 2 weeks. Page 15 IMNL-003.181008 © Ecoflo Wastewater Management Pty Ltd...
  • Page 16: Composting Accelerators

    Any staining of the pedestal can also be removed with the spray. Nature Quick Microbes Should be used each time a chamber is changed to kick start the process in the new chamber. Contact Ecoflo for further supplies when required Page 16 IMNL-003.181008 © Ecoflo Wastewater Management Pty Ltd...
  • Page 17 Fan and Insect Screen: Every month check that the fan is turning freely and clean the hole at the bottom of the moisture trap as well as the fly screen inside the trap. Page 17 IMNL-003.181008 © Ecoflo Wastewater Management Pty Ltd...
  • Page 18: Exchanging The Compost Chamber

    Release the Cam-lock levers & pull out the hose. Place Dust-Plug into Cam-Lock & lock levers. Replace the full cham- ber with empty one & connect the hose to the Cam-lock on the latter. Page 18 IMNL-003.181008 © Ecoflo Wastewater Management Pty Ltd...
  • Page 19 Nature Quick Mi- crobes as per the instruc- tions on the packaging or several scoops of compost from the hole after a cou- ple days of using the toilet. Page 19 IMNL-003.181008 © Ecoflo Wastewater Management Pty Ltd...
  • Page 20: Trouble Shooting

    If you need to change your ‘In-service’ chamber and the ‘Out-of-service’ chamber is not yet compost- ed dispose of the waste as normal and order a new chamber from Ecoflo. If the ‘half-life’ is too great, we suggest ordering a chamber with a Heating Pad for the winter months.
  • Page 21 7-amp hour battery whenever the mains power goes down. Helpful Hints from our customers : Paint the Vent Stack black to produce an upward air flow. Add a wind assisted turbo vent to the Vent Stack. Page 21 IMNL-003.181008 © Ecoflo Wastewater Management Pty Ltd...
  • Page 22: Product & Component Warranty

    Items subject to a dispute, where photographic evidence is inconclusive, must be sent prepaid to Ecoflo. The cost will be reimbursed by Ecoflo should the claim be found valid. In addition to the above, Ecoflo will only replace a fan that fails during the warranty period under the following conditions: •...
  • Page 23: Maintenance Schedule

    Please place this maintenance schedule close to your ‘In-service’ Chamber and complete the table as you rotate your chambers. Model: Nature Loo Excelet CS & Excelet Date First Put into Service: _____/_____/________ The ‘Out-of-service’ chamber must compost for a minimum of 5 months from the date it was first rotated ‘Out-of-service’.
  • Page 24 APPENDIX 1 Page 24 IMNL-003.181008 © Ecoflo Wastewater Management Pty Ltd...