Ecoflo Nature Loo Classic 850 Installation & Maintenance Manual

Advertisement

Quick Links

Thank you for purchasing the Classic 850. Please read this manual carefully before installation.
"Nature Loo" is a brand of Ecoflo Wastewater Management Pty Ltd.
Visit our website at ecoflo.com.au
IMNL-008-24.04.2020
Classic 850
Installation & Maintenance Manual
© Ecoflo Wastewater Management Pty Ltd
®

Advertisement

Table of Contents
loading

Summary of Contents for Ecoflo Nature Loo Classic 850

  • Page 1 Installation & Maintenance Manual ▪ Thank you for purchasing the Classic 850. Please read this manual carefully before installation. ▪ “Nature Loo” is a brand of Ecoflo Wastewater Management Pty Ltd. ▪ Visit our website at ecoflo.com.au IMNL-008-24.04.2020 © Ecoflo Wastewater Management Pty Ltd...
  • Page 2 Copyright © 2020 Ecoflo Wastewater Management Pty Ltd Please call your local distributor or Ecoflo Wastewater Management for support if required. Ecoflo Wastewater Management Pty Ltd www.ecoflo.com.au www.natureloo.com.au Phone: 1300 138 182 Phone: 07 3889 6144 Email: info@ecoflo.com.au Proudly Designed and Assembled in Australia...
  • Page 3: Table Of Contents

    COMPOSTING ACCELERATORS ..................... 15 CARE & MAINTENANCE ......................16 ROTATION OF CHAMBERS ...................... 17 TROUBLE SHOOTING ....................... 18 PRODUCT & COMPONENT WARRANTY ................. 19 MAINTENANCE SCHEDULE ..................... 21 APPENDIX 1 ..........................22 Page 3 IMNL-008-24.04.2020 © Ecoflo Wastewater Management Pty Ltd...
  • Page 4: What's In The Box

    0.30 cubic metre 20 mm Aggregate  50mm PVC pipe to connect the hose to the agricultural pipe  Purchase a Drain Kit from Ecoflo. The following tools will be required to complete the installation: Page 4 IMNL-008-24.04.2020 © Ecoflo Wastewater Management Pty Ltd...
  • Page 5: Classic 850 Schematics

    If you are planning to excavate an area under the house for the compost chambers, please ensure the area is well-drained and any retaining walls are built to the satis- faction of the local authority. Page 5 IMNL-008-24.04.2020 © Ecoflo Wastewater Management Pty Ltd...
  • Page 6: Installation

    Step 1: Positioning the Pedestal Diagram Locate the approximate area where you want the pedestal to go before cutting the hole. The usual position for pedestals is centred between side walls. Page 6 IMNL-008-24.04.2020 © Ecoflo Wastewater Management Pty Ltd...
  • Page 7: Step 2: Positioning The Waste Chute

    Step 2: Positioning the Waste Chute A 240mm hole must be cut in the toilet room floor to accommodate the waste chute. Draw a 240mm Waste Chute Hole Diameter circle Page 7 IMNL-008-24.04.2020 © Ecoflo Wastewater Management Pty Ltd...
  • Page 8: Step 3: Installing The Waste Chute

    Step 3: Installing the Waste Chute First ensure the pad or ground level on which the ‘In-service’ chamber will reside is at its final level beneath the toilet room. Waste Chute Flange Page 8 IMNL-008-24.04.2020 © Ecoflo Wastewater Management Pty Ltd...
  • Page 9 Extra Length Required for Under-floor Areas Page 9 IMNL-008-24.04.2020 © Ecoflo Wastewater Management Pty Ltd...
  • Page 10: Step 4: Installing The Pedestal

    Step 4: Installing the Pedestal Trim the waste chute flange carefully if necessary. Run a 10mm bead of silicone sealant around the waste chute Page 10 IMNL-008-24.04.2020 © Ecoflo Wastewater Management Pty Ltd...
  • Page 11: Step 5: Installing The Wheels To The Composting Chamber

    (A brush seal is supplied & fitted to the ‘In-service’ lid and acts as a seal to prevent any odour emitting from the chamber.) 1. Add 50mm Bulking Agent to 2. Close the Bungee Loops the Chamber Page 11 IMNL-008-24.04.2020 © Ecoflo Wastewater Management Pty Ltd...
  • Page 12: Step 7: Connecting The Vent Pipe And Fan To The 'In-Service' Chamber

    Ensure the fan is kept out of the weather to increase its longevity. Do not glue the fan housing to the ‘Y’ piece so the fan can be replaced, if required. Page 12 IMNL-008-24.04.2020 © Ecoflo Wastewater Management Pty Ltd...
  • Page 13: Connect The Flexible Air Hose & Excess Fluid Hose To The Chambers

    Connect the Flexible Air Hose & Excess Fluid Hose to the Chambers: Page 13 IMNL-008-24.04.2020 © Ecoflo Wastewater Management Pty Ltd...
  • Page 14: Powering Your Fan

    Hose should run into either a length of 50mm PVC pipe; drilled to allow liquid to escape, OR a length of slotted Ag pipe buried in the absorption trench as shown in the diagram. Both chambers should be connected. Page 14 IMNL-008-24.04.2020 © Ecoflo Wastewater Management Pty Ltd...
  • Page 15: Composting Accelerators

    Any staining of the pedestal can also be removed with the spray. Nature Quick Microbes Should be used each time a chamber is changed to kick start the process in the new chamber. Check Ecoflo Online Store for Consumables. Page 15 IMNL-008-24.04.2020 © Ecoflo Wastewater Management Pty Ltd...
  • Page 16: Care & Maintenance

    Clean restroom & toilet fixtures using only biodegradable cleaners. • Add 1 cup of bulking agent to toilet after every solid use. Check Ecoflo Online Store for Consumables. Monthly • Inspect the ‘In-service’ chamber, depends on usage, prepare another ‘In-service’ cham- ber for use once the chamber becomes full (refer to Rotation of Chambers).
  • Page 17: Rotation Of Chambers

    If the ‘Out-of-service’ chamber is to be placed away from the Main Vent assembly, you will need to dig a small second trench (20 x 20 x 20cms) to allow residual liquid to exit the cham ber. Page 17 IMNL-008-24.04.2020 © Ecoflo Wastewater Management Pty Ltd...
  • Page 18: Trouble Shooting

    If you need to change your ‘In-service’ chamber and the ‘Out-of-service’ chamber is not yet composted dispose of the waste as normal and order a new chamber from Ecoflo. Page 18 IMNL-008-24.04.2020...
  • Page 19 7-amp hour battery whenever the mains power goes down. Helpful Hints from our customers : Paint the Vent Stack black to produce an upward air flow. Add a wind assisted turbo vent to the Vent Stack. Page 19 IMNL-008-24.04.2020 © Ecoflo Wastewater Management Pty Ltd...
  • Page 20: Product & Component Warranty

    Items subject to a dispute, where photographic evidence is inconclusive, must be sent prepaid to Ecoflo. The cost will be reimbursed by Ecoflo should the claim be found valid. In addition to the above, Ecoflo will only replace a fan that fails during the warranty period under the following conditions: •...
  • Page 21: Maintenance Schedule

    Please place this maintenance schedule close to your ‘In-service’ Chamber and complete the table as you rotate your chambers. Model: Nature Loo Classic 850 Date First Put into Service: _____/_____/________ The ‘Out-of-service’ chamber must compost for a minimum of 5 months from the date it was first rotated ‘Out-of-service’.
  • Page 22 APPENDIX 1 Page 22 IMNL-008-24.04.2020 © Ecoflo Wastewater Management Pty Ltd...

Table of Contents