nect the provided 100mm vent cowl to the top of the
vent pipe, and then the bottom of the vent pipe into the
fan housing (do not glue this into the fan housing).
the 100mm DWV PVC pipe as per Option 1 or Option 2 (pictured above). If possible, Op-
tion 1 is far better for ventilation as the two 45 degree elbows in Option 2 can slow the air
IMNL-003.181008
© Ecoflo Wastewater Management Pty Ltd
Purchase sufficient length(s) of 100mm
PVC vent pipe such that the vent will ex-
tend 600mm (2 feet) above the highest
point of the roof. Take the fan housing
provided to the plumbing store if you
aren't sure which type to purchase.
All PVC pipe components, except all
components attached to the T piece
(including the fan housing) should be
glued together using Plumbers PVC
glue.