Technical Data; Electrical Data - Riello RS 300/M BLU Installation, Use And Maintenance Instructions

Forced draught gas burners
Table of Contents

Advertisement

TECHNICAL DATA

Model
Type
max.
Output
(1)
min.
Fuel
Gas pressure at maximum delivery.
Gas: G20/g25
Operation
Standard applications
Ambient temperatur
Combustion air temperature
Noise levels
Sound pressure
(3)
Sound power
Reference conditions: Ambient temperature 20°C - Gas temperature 15°C - Barometric pressure 1013 mbar - Altitude 0 m a.s.l.
(1)
Pressure at pressure switch test point 20)(A)p.12 with zero pressure in the combustion chamber and maximum burner output.
(2)
Sound pressure measured in manufacturer's combustion laboratory, with burner operating on test boiler and at maximum rated output. The
(3)
sound power is measured with the "Free Field" method, as per EN 15036, and according to an "Accuracy: Category 3" measuring accuracy, as
set out in EN ISO 3746.

ELECTRICAL DATA

Model
Type
Electrical supply
Fan motor IE2
Ignition transformer
Electrical power consumption
Electrical protection
Model
Type
Electrical supply
Fan motor IE3
Ignition transformer
Electrical power consumption
Electrical protection
RS 300/M BLU
859 T
kW
1350 - 3800
kW
500
(2)
mbar
23.3 / 32.7
°C
°C max
82
dB(A)
93
RS 300/M BLU
859 T
3N ~ 400/230V
+/-10% 50 Hz
rpm
2900
V
230/400
kW
4,5
A
15/9,1
V1 - V2
I1 - I2
kW max
3N ~ 400V +/-10% 50 Hz
rpm
V
kW
A
V1 - V2
I1 - I2
kW max
RS 300/M BLU
859 T80
1350 - 3800
500
Natural gas: G20 (methane) - G21 - G22 - G23 - G25
23.3 / 32.7
Intermittent
Boilers: water, steam, diathermic oil
0 - 40
60
82
93
RS 300/M BLU
859 T80
3N ~ 380/220V
+/-10% 60 Hz
3480
220/380
4,5
16,6/9,6
230 V - 1 x 8 kV
1 A - 20 mA
4,5
IP 54
RS 400/M BLU
860 T
2920
400/690
7,5
14/8.1
230 V - 1 x 8 kV
1 A - 20 mA
8.8
IP 54
8
RS 400/M BLU
RS 400/M BLU
860 T
856 T80
1830 - 4590
1830 - 4590
950
950
34.3 / 40.2
34.3 / 40.2
85
88
96
99
RS 400/M BLU
RS 400/M BLU
860 T
860 T80
3N ~ 400V
3N ~ 380V
+/-10% 50 Hz
+/-10% 60 Hz
2900
3320
400/690
380/660
7,5
7,5
13,8/8
14,7/8,5
9.2
RS 400/M BLU
860 T80
3N ~ 380V +/-10% 60 Hz
3320
380/660
7.5
14.5/8.4
8.9

Advertisement

Table of Contents
loading

Table of Contents